`_separately_timed_dhw` returned True for any boiler+cylinder+from-main
cert, applying the SAP 10.2 Table 2b note b) ×0.9 temperature-factor
reduction unconditionally. For the lpg-boiler "before" worksheet (pre-
1998 LPG boiler SAP code 115 + 210 L cylinder, NO cylinder thermostat,
control 2113 "Room thermostat and TRVs" — no programmer) this dropped
the (53) temperature factor to 0.702 (= 0.60 × 1.3 × 0.9) where the
worksheet lodges 0.78 (= 0.60 × 1.3), under-counting cylinder storage
loss (55) by ~119 kWh/yr and over-rating SAP by ~0.25.
RdSAP 10 §10.5 (PDF p.57) "Hot water separately timed":
No programmer, pre-1998 boiler → No
Programmer, pre-1998 boiler → Yes
Post-1998 boiler → Yes
DHW is therefore NOT separately timed only when a pre-1998 boiler is
paired with a no-programmer control. Add the two SAP 10.2 Table 4c(2) /
Table 4b lookups (controls without a programmer = {2101, 2103, 2111,
2113}; pre-1998 gas/LPG boilers 110-119 + oil 124/125/128) and return
False for that combination; every other boiler+cylinder cert keeps the
separately-timed default, so the change is confined to old low-control
stock and the heating corpus + goldens are unchanged.
Effect: the full chain (Summary PDF → extractor → mapper → cert_to_inputs
→ calculator) now reproduces the lpg-boiler worksheet's §11a unrounded
SAP -6.6499 at abs < 1e-4 (was -6.4013). Full regression suite green bar
the 3 pre-existing unrelated fails.