Model/tests/domain/sap10_calculator
Khalim Conn-Kowlessar 00921f71e8 fix(water-heating): heat-network primary loss uses Table 3 h=3 all months
SAP 10.2 Table 3 (PDF p.160) verbatim: "For heat networks apply the
formula above with p = 1.0 and h = 3 for all months." The primary
circulation hours for a heat-network main are fixed at h=3 winter and
summer, independent of the cylinder-thermostat / separate-timing
lodgement that selects the h=5/h=11 rows for boiler systems.

`primary_loss_monthly_kwh` / `primary_circuit_hours_per_day_table_3` gain
a `heat_network` flag (→ (3, 3)); `_primary_loss_override` passes
`_is_heat_network_main(main)`. p=1.0 was already pinned via
`_HEAT_NETWORK_PIPEWORK_INSULATION_FRACTION`; only the hours were wrong.

Before, cert 8536 routed through the h=5/3 row because its community
biomass DHW fuel (31) collides with electricity code 31, so
`_separately_timed_dhw` returned False. The Table 3 heat-network rule
overrides that path: 8536 primary loss (59) 335.81 → 273.90, EXACT to
the faithful case-32 worksheet (storage (56) 376.58 also matches 376.94).

API eval within-0.5 57.0% → 56.9% (one offsetting-error cert crosses
out; signed err −0.205 → −0.202). Applied spec-uniformly per the
determinism principle — the heat-network primary hours are unambiguous.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 20:12:49 +00:00
..
climate Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
rdsap fix(water-heating): heat-network primary loss uses Table 3 h=3 all months 2026-06-10 20:12:49 +00:00
validation Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
worksheet fix(wall-U): apply RdSAP Table 4 "Sheltered" R=0.5 to alternative walls 2026-06-08 22:49:42 +00:00
__init__.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_bre_worked_examples.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_calculator.py feat(calculator): thread per-end-use fuel codes + PV export onto SapResult 2026-06-05 18:59:24 +00:00
test_pcdb_etl.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_322_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_329_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_362_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_postcode_weather.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12a.py fix(tariff): Unknown meter + storage/CPSU main → off-peak (§12) 2026-06-06 19:02:34 +00:00
test_table_13.py fix(hw-cost): WHC-903 immersion off-peak HW bills at Table 13 high-rate fraction 2026-06-08 15:45:41 +00:00