SAP 10.2 Table 12a (PDF p.191) is titled "High-rate fractions for systems
using 7-hour and 10-hour tariffs"; its "Immersion water heater" row lists
the tariff as "7-hour or 10-hour" only, routing to Table 13. An 18-hour or
24-hour tariff is OUTSIDE the table's scope — it provides at least 18
hours/day at the low rate, more than enough to heat any immersion cylinder
off-peak, so the high-rate fraction is 0 (all DHW billed at the low rate).
`electric_dhw_high_rate_fraction` previously mapped 18-/24-hour to the
10-hour equations (returning ~0.10 for a 110 L dual immersion) on an
over-literal reading of Table 13 Note 1 ("at least 10 hours"). The Elmhurst
dr87 worksheet for solid fuel 5 (cert 001431: 18-hour meter, 110 L dual
immersion, WHC 903) refutes that: HW (245) high-rate = 0.0 kWh, (246)
low-rate = 100%. Table 12a's title bounds the table to the two named
tariffs; 18-/24-hour fall outside it.
Resolves the Table-13 blocker on the immersion-extractor fix: once the
Summary extractor captures the dual immersion, the 18-hour solid-fuel
corpus certs stay at high_frac=0 (matching their worksheets) instead of
regressing to the 10-hour-column 0.10.
API SAP eval unchanged: 57.6% within 0.5, mean|err| 1.185, signed -0.165
(the cached sample has no 18-hour WHC-903 certs; one 24-hour cert shifts
sub-threshold). Regression gate green (3 pre-existing fails unrelated).