from typing import Dict, Union
|
|
from model_data.BaseUtility import Definitions
|
|
from model_data.epc_attributes.attribute_utils import clean_description, find_keyword
|
|
|
|
|
|
class MainheatControlAttributes(Definitions):
|
|
# These systems allow for the automatic regulation of temperature
|
|
THERMOSTATIC_CONTROL_KEYWORDS = [
|
|
'room thermostats',
|
|
'appliance thermostats',
|
|
'room thermostat',
|
|
'temperature zone control',
|
|
'time and temperature zone control',
|
|
'celect-type control' # This is a specific type of thermostat controls
|
|
# 'no thermostatic control',
|
|
# 'no room thermostat'
|
|
]
|
|
|
|
# TRVs stands for Thermostatic Radiator Valves which control the heating temperature of individual radiators
|
|
# This is split out distinctly
|
|
TRVS_KEYWORDS = [
|
|
'trvs',
|
|
]
|
|
|
|
# These systems provide a way to store and manage energy usage
|
|
CHARGING_SYSTEM_KEYWORDS = [
|
|
'charging system',
|
|
'automatic charge control',
|
|
'manual charge control',
|
|
'flat rate charging',
|
|
'high heat retention storage heaters'
|
|
]
|
|
|
|
# These systems are mainly focused on on/off operations
|
|
SWITCH_SYSTEM_KEYWORDS = [
|
|
'programmer',
|
|
]
|
|
|
|
# These systems enhance operation, efficiency, or safety. e.g. a boiler energy manager
|
|
# manages the efficiency of boiler operation. There is an argument to separate 'boiler energy manager' and 'bypass'
|
|
AUXILIARY_SYSTEM_KEYWORDS = [
|
|
'boiler energy manager',
|
|
'bypass',
|
|
'flow switch',
|
|
]
|
|
|
|
# These keywords indicate a lack of control system
|
|
NO_CONTROL_SYSTEM_KEYWORDS = [
|
|
'no time or thermostatic control',
|
|
'no thermostatic control',
|
|
'none',
|
|
'no room thermostat'
|
|
]
|
|
|
|
# These systems provide control specifically for Domestic Hot Water
|
|
DHW_CONTROL_KEYWORDS = [
|
|
'dhw only'
|
|
]
|
|
|
|
# This system indicates the use of community heating
|
|
COMMUNITY_HEATING_KEYWORDS = [
|
|
'use of community heating'
|
|
]
|
|
|
|
MULTIPLE_ROOM_THERMOSTATS_PHRASES = [
|
|
'at least two room stats',
|
|
'at least two room thermostats'
|
|
]
|
|
|
|
RATE_CONTROL_KEYWORDS = [
|
|
'single rate heating',
|
|
]
|
|
|
|
# Sufficiently similar descriptions to be remapped
|
|
TO_REMAP = {
|
|
"celect control": 'celect-type control',
|
|
"celect controls": 'celect-type control',
|
|
}
|
|
|
|
WELSH_TEXT = {
|
|
"rhaglennydd, dim thermostat ystafell": "programmer, no room thermostat",
|
|
"rhaglennydd a thermostat ystafell": "programmer and room thermostat",
|
|
"rheoligçör t+ól +ó llaw": "manual charge control",
|
|
"rheoli'r t+ól +ó llaw": "manual charge control",
|
|
"rheolaeth amser a rheolaeth parthau tymheredd": "time and temperature zone control",
|
|
"rhaglennydd a thermostatau ar y cyfarpar": "programmer, room thermostat",
|
|
"rheolyddion i wresogyddion storio sygçön cadw llawer o wres": "controls for high heat retention storage "
|
|
"heaters",
|
|
"t+ól un gyfradd, rhaglennydd a thermostat ystafell": "single rate heating, programmer and room thermostat",
|
|
"rhaglennydd ac o leiaf ddau thermostat ystafell": "programmer and at least two room thermostats",
|
|
"thermostat ystafell yn unig": "room thermostat only",
|
|
"dim rheolaeth amser na rheolaeth thermostatig ar dymheredd yr ystafell": "no time or thermostatic control of "
|
|
"room temperature",
|
|
"rheoli gwefr drydanol yn awtomatig": "automatic charge control",
|
|
'system dalu wedigçöi chysylltu +ó defnyddio gwres cymunedol, thermostat ystafell yn unig': "charging system "
|
|
"linked to use of"
|
|
" community "
|
|
"heating, "
|
|
"room thermostat "
|
|
"only",
|
|
"dim": "none",
|
|
"dim rheolaeth thermostatig ar dymheredd yr ystafell": "no thermostatic control of room temperature",
|
|
"thermostatau ar y cyfarpar": "appliance thermostats",
|
|
"rhaglennydd a thermostatau ystafell": "programmer and room thermostats",
|
|
"system dalu wedigçöi chysylltu +ó defnyddio gwres cymunedol, rhaglennydd a thermostat ystafell":
|
|
"charging system linked to use of community heating, programmer and room thermostat",
|
|
'system dalu wedigçöi chysylltu +ó defnyddio gwres cymunedol, rhaglennydd a trvs':
|
|
"charging system linked to use of community heating, programmer and trvs",
|
|
'system dalu wedigçöi chysylltu +ó defnyddio gwres cymunedol, trvs':
|
|
'charging system linked to use of community heating, trvs',
|
|
't+-ól un gyfradd, trvs': 'single rate heating, trvs',
|
|
't+ól un gyfradd, rhaglennydd a trvs': 'single rate heating, programmer, trvs',
|
|
't+ól un gyfradd, trvs': 'single rate heating, trvs',
|
|
'trvs a falf osgoi': 'trvs and bypass'
|
|
}
|
|
|
|
def __init__(self, description: str):
|
|
self.description: str = clean_description(description.lower()).strip()
|
|
self.nodata = not self.description or description in self.DATA_ANOMALY_MATCHES
|
|
|
|
translation = self.WELSH_TEXT.get(self.description)
|
|
if translation:
|
|
self.nodata = False
|
|
self.description = translation
|
|
|
|
# Remap
|
|
remapped = self.TO_REMAP.get(self.description)
|
|
if remapped:
|
|
self.description = remapped
|
|
|
|
if not self.nodata:
|
|
if not any(
|
|
self._keyword_in_description(keywords)
|
|
for keywords in [
|
|
self.THERMOSTATIC_CONTROL_KEYWORDS,
|
|
self.CHARGING_SYSTEM_KEYWORDS,
|
|
self.SWITCH_SYSTEM_KEYWORDS,
|
|
self.DHW_CONTROL_KEYWORDS,
|
|
self.COMMUNITY_HEATING_KEYWORDS,
|
|
self.TRVS_KEYWORDS,
|
|
self.NO_CONTROL_SYSTEM_KEYWORDS,
|
|
self.RATE_CONTROL_KEYWORDS
|
|
]
|
|
):
|
|
raise ValueError('Invalid description')
|
|
|
|
def _keyword_in_description(self, keywords):
|
|
return any(keyword in self.description for keyword in keywords)
|
|
|
|
def process(self) -> Dict[str, Union[str, bool, None]]:
|
|
|
|
if self.nodata:
|
|
result = {
|
|
"thermostatic_control": False,
|
|
"charging_system": False,
|
|
"switch_system": False,
|
|
"no_control": False,
|
|
"dhw_control": False,
|
|
"community_heating": False,
|
|
"multiple_room_thermostats": False,
|
|
"auxiliary_systems": False,
|
|
"trvs": False,
|
|
"rate_control": False
|
|
}
|
|
return result
|
|
|
|
result: Dict[str, Union[str, bool, None]] = {
|
|
"thermostatic_control": find_keyword(self.description, self.THERMOSTATIC_CONTROL_KEYWORDS),
|
|
"charging_system": find_keyword(self.description, self.CHARGING_SYSTEM_KEYWORDS),
|
|
"switch_system": find_keyword(self.description, self.SWITCH_SYSTEM_KEYWORDS),
|
|
"no_control": find_keyword(self.description, self.NO_CONTROL_SYSTEM_KEYWORDS),
|
|
"dhw_control": find_keyword(self.description, self.DHW_CONTROL_KEYWORDS),
|
|
"community_heating": find_keyword(self.description, self.COMMUNITY_HEATING_KEYWORDS),
|
|
"multiple_room_thermostats": any(
|
|
phrase in self.description for phrase in self.MULTIPLE_ROOM_THERMOSTATS_PHRASES
|
|
),
|
|
"auxiliary_systems": find_keyword(self.description, self.AUXILIARY_SYSTEM_KEYWORDS),
|
|
"trvs": find_keyword(self.description, self.TRVS_KEYWORDS),
|
|
"rate_control": find_keyword(self.description, self.RATE_CONTROL_KEYWORDS),
|
|
}
|
|
|
|
if result["no_control"] == 'no room thermostat':
|
|
result["thermostatic_control"] = None
|
|
|
|
return result
|