The Elmhurst Summary §14.0 "Main Heating EES Code" is a three-letter
identifier that resolves to the specific fuel for solid-fuel main
heating systems. The §14.0 "Main Heating SAP Code" alone can't
disambiguate because Table 4a categorises solid-fuel systems by
appliance type rather than fuel — SAP code 160 ("Closed room heater
with boiler") is shared by anthracite, wood chips, dual fuel and
smokeless across the heating-systems corpus.
Three changes land together:
1. `MainHeating` dataclass (`elmhurst_site_notes.py`) gains a
`main_heating_ees: str = ""` field for the §14.0 EES code.
2. `ElmhurstSiteNotesExtractor._extract_main_heating` reads "Main
Heating EES Code" from §14.0.
3. `_map_elmhurst_sap_heating` adds a fourth fuel-derivation
fallback (after the existing electric-SAP-code + §15.0-liquid-
fuel branches): when `main_fuel_int is None` and the §14.0 EES
code is in `_ELMHURST_MAIN_HEATING_EES_TO_FUEL_CODE`, use that
dict's value as the main fuel.
Dict (corpus-derived, 10 entries → 7 distinct Table 32 fuels):
BAF, BAI, RAM → 15 anthracite (3.64 / 0.395 / 1.064)
BCC → 11 house coal (3.67 / 0.395 / 1.064)
BDI → 10 dual fuel (3.99 / 0.087 / 1.049)
BKI → 12 smokeless (4.61 / 0.366 / 1.261)
BQI → 21 wood chips (3.07 / 0.023 / 1.046)
RPS → 22 wood pellets bags (5.81 / 0.053 / 1.325)
RUN → 23 bulk pellets (5.26 / 0.053 / 1.325)
RWN → 20 wood logs (4.23 / 0.028 / 1.046)
Dict values are Table 32 fuel codes, NOT API `main_fuel` enum codes
— the API codes 1-9 collide with Table 32 codes for unrelated fuels
(e.g. API 5 = "anthracite" vs Table 32 5 = "bottled LPG main
heating"). `unit_price_p_per_kwh` / `co2_factor_kg_per_kwh` /
`primary_energy_factor` all check the Table 32 dict before falling
through to the API translation, so using Table 32 codes here avoids
the collision and routes cost/CO2/PE through the correct fuel row.
Heating-systems corpus impact — all 10 solid-fuel variants move
from `_BLOCKED_BY_MISSING_MAIN_FUEL_TYPE` (assert-on-raise) back
onto the residual-pin grid in `_EXPECTATIONS`:
variant ΔSAP Δcost ΔCO2 ΔPE
solid fuel 2 +4.79 -£110 -484 kg +441 kWh anthracite
solid fuel 3 +4.43 -£102 -1206 +1452 anthracite
solid fuel 4 +4.13 -£95 -714 +1655 anthracite
solid fuel 5 +2.71 -£62 -301 +2360 house coal — smallest
solid fuel 6 -7.38 +£168 -154 +2519 dual fuel — only negative
solid fuel 7 +5.82 -£131 -758 +2968 smokeless
solid fuel 8 +4.24 -£98 -15 +2513 wood chips
solid fuel 9 +3.44 -£79 -8 +2428 wood pellets bags
solid fuel 10 +5.14 -£118 -53 +1849 wood pellets bulk
solid fuel 11 +4.35 -£100 -9 +1536 wood logs
Remaining residuals trace to heating-system efficiency / control
type — separate slices. 16 variants still in `_BLOCKED`: community
heating ×5, electric storage ×4, no system, oil non-Heating-oil ×5,
Bulk LPG ×1. Each is its own derivation slice.
Extended handover suite at HEAD post-slice: 876 pass / 0 fail (was
875 + 1 new EES wiring AAA test).
Pyright net-zero on touched files (45 → 45 — all pre-existing).
No golden fixture impact — no golden cert lodges an EES code via
the Elmhurst path.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||
| epc | ||
| magicplan | ||
| __init__.py | ||
| datatypes.py | ||
| enums.py | ||