The §11 layout parser keys a window's wall Location on the glazing-prefix /
orientation tokens around its data row. An alt-wall window lodges its
"Alternative wall 1" Location wrapped across the lines bracketing the W×H×A
row. For a DOUBLE-glazed alt window the prefix line also carries the glazing
phrase ("Double between 2002 Alternative wall"), so the partition breaks
there and the location survives into the window's pre-data slice. For a
SINGLE-glazed alt window the "Alternative wall" line stands alone with no
glazing-type word, so _partition_after_manuf scanned past it and swallowed
it into the PREVIOUS window's suffix — the window then defaulted to
"External wall" and its opening deducted from the wrong wall.
Fix: treat a standalone wall-location line ("Alternative wall" / "External
wall" / "Party wall") as a window boundary in _partition_after_manuf, so it
attaches to the following window's prefix. Surfaced by simulated case 34
(cert 001431 electric-storage flat): 2 of 4 single-glazed alt-wall windows
were mis-allocated, splitting 2.75/10.78 m² instead of the worksheet's
4.63/8.90 corridor/external opening areas.
Elmhurst-extractor only; API gauge unaffected. Regression gate green (3
pre-existing fails unrelated); worksheet harness 47/47 unchanged. Case 34's
alt-wall opening area now matches the worksheet; the corridor wall net area
is correct (the cert's residual is now isolated to the unheated-corridor
door, a separate slice).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||
| fixtures | ||
| __init__.py | ||
| test_elmhurst_end_to_end.py | ||
| test_elmhurst_extractor.py | ||
| test_end_to_end.py | ||
| test_extractor.py | ||
| test_heating_systems_corpus.py | ||
| test_pdf.py | ||
| test_room_heater_worksheet_001431.py | ||
| test_summary_pdf_mapper_chain.py | ||