Cert 9390-2722-3520 (community mains-gas boiler scheme, sap_main_heating_
code=301, main_fuel_type=20) emitted CO2 0.44 t vs lodged 2.8 t — 6.4x low.
Root cause: the EPC `main_fuel_type` enum and the SAP Table 12 / Table 32
fuel-code numbering COLLIDE in the 18-25 range. Per
`datatypes/epc/domain/epc_codes.csv` (RdSAP-Schema-17.0) EPC fuel
20 = "mains gas (community)", but Table 12/32 code 20 is a solid biomass
fuel (CO2 0.028, PE 1.046, wood-logs price). The factor lookups
(`co2_factor_kg_per_kwh` / `primary_energy_factor` / `unit_price_p_per_kwh`)
check the Table-12/32 dict FIRST, so the EPC community fuel 20 silently
returned the biomass factor instead of translating 20 -> Table 12 code 51
(community mains gas: CO2 0.210, PE 1.130, mains-gas price).
Fix: new `_heat_network_factor_fuel_code(main)` translates the EPC community
fuel to its Table-12 code via `API_FUEL_TO_TABLE_12`, but ONLY for
heat-network mains (`_is_heat_network_main`) — a genuine biomass boiler
(non-community) keeps its raw Table-12 factor. Applied at the five
heat-network factor sites: space-heating CO2 / PE / unit-price and
water-heating (WHC 901) CO2 / PE. The Summary path is unaffected (it maps
"Mains gas - community" to code 1, no collision), so the community-heating
corpus (CH1-6) is untouched.
Worksheet-validated against simulated case 14 (community boilers + mains
gas, SAP code 301): worksheet (367) CO2 factor 0.2100, (467) PE factor
1.1300 — exactly the Table-12 code-51 values the translator now reaches.
9390 CO2 0.44 -> 3.03 t (lodged 2.8; spec-correct factors over the API-only
register residual per [[feedback-worksheet-not-api-reference]]), PE 204 ->
220 (the spec-correct 1.13 factor; the prior 204≈205 match was the
collision coinciding with the register residual). 9390 is unpinned (retired
at P2.2 per ADR-0010 §10); the translator is locked by two unit tests.
REMAINING (separate follow-up): 9390 SAP +4 is a cost-side gap — the
heat-network cost path does not apply the 1/heat_source_eff (1/0.80)
scaling that the CO2/PE paths do, so community fuel cost under-counts.
Suite: 2616 passed, 1 skipped (community corpus green); the 2
test_rdsap_uvalues stone-formula failures are pre-existing (HEAD
|
||
|---|---|---|
| .. | ||
| applications | ||