The PV-array (ea7f4f43) and electricity-tariff (6ec09892) mapper fixes shifted
the observed output of five frozen gates that weren't updated alongside:
- has_pv component-accuracy floor 0.9798 -> 0.9697: carrying full-SAP lodged PV
now reads the true has_pv=True for full-SAP PV dwellings, so the leave-one-out
scorer's actual changes (ground-truth-method shift, ADR-0037 pattern).
- uprn_10093116528 80->... pin 82 -> 83: tariff=1 (standard) was wrongly read as
dual/Economy 7; translating to "single" re-prices the gas semi's electricity.
- uprn_10096028301 82 -> 84, uprn_10023444324 80 -> 82 (== lodged 82),
uprn_10023444320 81 -> 83: now credit the lodged sap_energy_source.pv_arrays
the schema previously dropped. Comments document the per-cert PV/Elmhurst
relationship (incl. the mid-floor sibling landing +2 over its lodged integer).
Pre-existing, unrelated failures untouched: the missing
sap_16_0_full_no_floor_dims.json fixture and the RdSAP-21 floor-area test (both
reproduce on origin/main).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>