The Summary-path mapper raised UnmappedElmhurstLabel for a §15.1 "Cylinder Insulation Type: Jacket" lodging — only "Foam" (→1, factory) was mapped. SAP10 cylinder_insulation_type uses 2 for loose jacket (matching the GOV.UK API codes), and SAP 10.2 Table 2 Note 1 gives it a separate ~2× storage-loss factor that the cascade now handles (S0380.224). Add "Jacket" → 2 for cross-mapper parity with the API path and so the loose-jacket storage-loss branch fires on the Summary path. Surfaced by simulated case 19 (a 210 L jacket cylinder + electric storage heaters), which previously couldn't extract at all. §4 suite 2397 passed; mapper.py pyright unchanged at 32. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> |
||
|---|---|---|
| .. | ||