Model/tests
Jun-te Kim 11a637c6bd test(accuracy): ratchet 77.0% -> 77.3% via unsized-cylinder storage-loss fix
A hot-water cylinder lodging gov-API `cylinder_size=0` ("size not
determined", with has_hot_water_cylinder=true) resolved to a None volume
in `_cylinder_storage_loss_override` (which reads `_cylinder_volume_l_
from_code`, returning None for code 0). The subsequent `if volume_l is
None: return None` then DROPPED the cylinder's Table-2 storage loss
entirely — under-costing the DHW and over-rating the dwelling. Meanwhile
the Table-13 high-rate-fraction path already used `_hot_water_cylinder_
volume_l` (which defaults size 0 to 110 L), so the two DHW paths
disagreed on the same cylinder.

RdSAP 10 §10.5 Table 28 ("if the actual size is not determined, the size
is taken as according to Table 28") makes an unsized present cylinder the
110 L "Normal" baseline, which STILL incurs the storage loss. Fixed by
defaulting the storage-loss volume to 110 L for the explicit size-0 case.

Gated on the EXPLICIT 0 (not None): a full-SAP cert whose RdSAP
cylinder_size is simply unlodged (None, e.g. pinned 10091568921) keeps
its own cylinder handling rather than a forced 110 L RdSAP default.

7 corpus certs lodge cylinder_size=0 + has_cylinder=true. Gauge: within
77.0% -> 77.3%, SAP MAE ~flat (0.648), CO2 0.074 -> 0.073, PE 3.2 -> 3.05
(the previously-dropped storage loss now correctly counted in the demand
cascade). Unit-pinned in test_cert_to_inputs (storage loss non-None for
size 0); RealCertExpectation 200004017091 = 71.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 23:02:27 +00:00
..
applications refetch_solar=False models with stored Solar insights and never calls Google 🟥 2026-07-02 14:19:31 +00:00
datatypes Normalize RdSAP insulated_door_u_value on the 20.0.0 + 21.0.0 paths 2026-07-01 14:48:25 +00:00
domain test(accuracy): ratchet 77.0% -> 77.3% via unsized-cylinder storage-loss fix 2026-07-02 23:02:27 +00:00
e2e Prove prediction resolves landlord overrides to a real cohort match end-to-end 🟩 2026-06-16 15:20:49 +00:00
fixtures/epc_prediction feat(epc-prediction): geo-proximity weighting, per-component (#1227) 2026-06-15 14:58:42 +00:00
harness Re-pin golden cert 0036 to expect the zoned tune-up its PCDB boiler now fires (#1399) 2026-07-01 22:56:12 +00:00
infrastructure test(accuracy): ratchet 77.0% -> 77.3% via unsized-cylinder storage-loss fix 2026-07-02 23:02:27 +00:00
lambdas new application to trigger e2e for a single property and scenario 2026-06-22 12:54:53 +00:00
magic_plan Mapper reads new 'Total Trickle Vent Effective Area' label 🟥 2026-06-30 12:56:54 +00:00
orchestration Fix integration test: LPG solid-brick dwelling now correctly offered HHRSH (#1378) 2026-07-01 11:14:36 +00:00
repositories Merge pull request #1373 from Hestia-Homes/fix/1361-class-b-predicted-null-lodged 2026-07-01 08:35:58 +01:00
scripts Pass new cylinder fields through _make_audit test helper 2026-07-02 15:57:04 +00:00
utilities task_handler passes orchestrator and task_id to wrapped function when flag is true 🟥 2026-06-24 10:47:05 +00:00
__init__.py added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
conftest.py Audit generator populates XLSX, uploads to S3, and records UploadedFile row 🟪 2026-06-09 12:05:55 +00:00
test_lambda_packaging.py better smoke tests to check what is failign 2026-06-17 11:53:33 +00:00