Khalim Conn-Kowlessar 138f5688e0 fix(pashub): wire the surveyed measured cylinder heat-loss factor
A PasHub survey can lodge a manufacturer's measured cylinder loss ("What is
the cylinder measured heat loss: 0.94 kWh/24 hours") — the SAP 10.2 §4
(48)-(50) declared-loss factor that must override the Table 2 V×L×VF
insulation computation. The site-notes path dropped it two ways: the
extractor looked for "Cylinder Measured Heat Loss:" (matches 0 fixtures) while
the PDF label is "What is the cylinder measured heat loss:" (92 fixtures), and
the mapper never wired `cylinder_heat_loss` even when captured. So the
calculator fell back to the age-band insulation default — a lossier cylinder
than surveyed — over-costing hot water and under-rating SAP.

Fix the extractor label and add `_pashub_cylinder_measured_heat_loss` (parses
the leading float, returns None for "Not known"), mirroring the gov-API and
Elmhurst paths that already pass `cylinder_heat_loss` through. 3 Woodmans
Court -1.33 → -0.09; LRHA cohort within-0.5 58.3% → 60.2%, MAE 0.515 → 0.496.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-28 09:22:05 +00:00
..
fixtures Re-pin Wythenshawe accuracy harness to the DB oracle (#1649) 2026-07-19 11:40:51 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py rename mains_gas to gas_connection_available 2026-07-01 10:50:58 +00:00
test_elmhurst_extractor.py fix(extractor): drop windows-table header remnant from first window glazing type 2026-06-02 22:54:49 +00:00
test_end_to_end.py PasHub SAP accuracy: infiltration inputs + immersion DHW + lights/lobby/heat-network (#1615) 2026-07-16 00:30:55 +01:00
test_extractor.py Model a PasHub dwelling's second main heating system 🟩 2026-07-24 15:45:47 +00:00
test_heating_systems_corpus.py Merge remote-tracking branch 'origin/main' into feature/per-cert-mapper-validation 2026-06-13 22:20:15 +00:00
test_pashub_sap_accuracy.py PasHub SAP accuracy: refresh 5 Paxton fixture to the current V5 (MEV) re-survey 🟩 2026-07-16 00:52:33 +00:00
test_pashub_sap_accuracy_lrha_wave3.py fix(pashub): wire the surveyed measured cylinder heat-loss factor 2026-07-28 09:22:05 +00:00
test_pashub_sap_accuracy_wythenshawe.py Record Elmhurst-validation provenance finding (#1649) 2026-07-20 09:16:54 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_room_heater_worksheet_001431.py S0380.239: system-build walls take masonry structural infiltration (0.35) 2026-06-05 19:00:02 +00:00
test_summary_pdf_mapper_chain.py fix(roof): bill at-rafters insulation on RdSAP 10 Table 16/18 column (2) 2026-06-16 04:42:44 +00:00