Model/backend/epc_api
Jun-te Kim 17ced10e94 test(accuracy): validate + pin 217091901 (single-glazing confirmed vs Elmhurst)
Top-floor flat, solid brick uninsulated, uninsulated flat roof, gas combi,
SINGLE glazing (glazed_type 5). Built in accredited Elmhurst RdSAP10 and every
heat-loss element matches the engine EXACTLY: walls 53.18, flat roof 145.57,
floor 0, party 0, and — with the faithful single glazing — windows 34.7114 W/K
(8.62 m2 x eff U 4.0268). Confirms the mapper's glazed_type 5 -> single (raw U
4.8) is spec-correct per epc_codes.csv, not the double it superficially
resembles. Engine 61 vs lodged 62; the -1.18 is a cost-side residual, not a
fabric bug. Pinned to the observed engine 61.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 04:16:47 +00:00
..
json_samples test(accuracy): validate + pin 217091901 (single-glazing confirmed vs Elmhurst) 2026-07-03 04:16:47 +00:00
api_spec.md adding hacky handling for matching on lmk key or uprn 2026-04-09 14:47:54 +01:00