Model/datatypes
Khalim Conn-Kowlessar 1ed6d06804 fix(mapper): drop only U=0 internal RR stud walls, keep positive-U ones
A Detailed room-in-roof lodges "Stud Wall" surfaces, but the cascade billed
every one through Table 17 from its insulation — over-counting fabric on
internal studs that carry no heat loss. sim case 20's two studs lodge §8.1
Default U-value 0.00 and the P960 worksheet omits them from BOTH fabric heat
loss (§3: (33)=285.9847) and total exposed area (31)=239.68; the cascade
computed ~0.52 each → (33) +4.16 W/K and continuous SAP 43.05 vs 43.6322.

Gate the drop on the lodged Default U-value: 0.00 → internal knee wall,
return None (no heat loss, no area); positive → a real exposed knee wall
(cert 000565 Ext2 Detailed: 0.31 / 0.10) that still falls through to the
Table-17 path. The earlier over-broad "drop all studs" zeroed 000565's
genuine studs — this keeps them.

Pins test_summary_001431_case20_fabric_heat_loss_matches_worksheet_line_33
((33)=285.9847 at 1e-4); case 20 continuous SAP now EXACT (43.6322). 2850
pass (the lone test_total_floor_area failure is pre-existing on base);
pyright strict net-zero (32=32).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 10:47:30 +00:00
..