Model/tests
Khalim Conn-Kowlessar 22fe4f41b8 fix(tariff): Unknown meter + dual electric immersion → off-peak per §12 (RdSAP 10 PDF p.62)
Supersedes the previous "verified non-fix" doc (3548f1f3): the spec DOES make
this a fix — Khalim was right that the Unknown-meter branch is driven by the
heating/water system, not a blanket STANDARD.

RdSAP 10 §12 (PDF p.62): "If the electricity meter is unknown, treat as single
meter EXCEPT where main heating OR WATER HEATING are intended to run off an
off-peak tariff (per systems listed in the text box above) ... If that results
in a dual meter, assign tariff per rules 1 to 4." The text-box off-peak systems
include DUAL ELECTRIC IMMERSION. Our `rdsap_tariff_for_cert` only triggered the
Unknown→off-peak exception on a storage/CPSU MAIN — it ignored the
dual-electric-immersion WATER-heating trigger, so an Unknown-meter dwelling
with a non-storage main (e.g. room heaters) + dual immersion was billed
STANDARD (13.19p flat) when it should be dual → Rules 1-4 on the main.

Fix: thread `water_is_off_peak_dual_immersion` (whc 903 + immersion lodged dual
via `_immersion_is_single is False`) into the Unknown-meter branch; when any
text-box trigger is present, resolve via the same Rules 1-4 dispatch (room
heaters → Rule 3 → 10-hour). Single-immersion / instantaneous (whc 909) certs
correctly stay STANDARD (no text-box system).

Worksheet-validated on "simulated case 48" (main 691 + Unknown meter + 903 dual
immersion): Elmhurst 10-Hour Off Peak, SAP 57; ours 45 → 55 (7-hour gives 45,
confirming 10-hour). Flips exactly ONE corpus cert — Apartment 241 (the genuine
-5.38 under-rater, main 691 + dual immersion) -5.38 → -1.05; every other
Unknown+dual-immersion cert already has a storage main (Rule 2). Corpus
within-0.5 holds 72.5%, MAE 0.793 → 0.789 (improved). CO2/PE unchanged.

GSHP/WSHP-main trigger (the other §12 Unknown exception bullet) is a separate
follow-up. Gates green: corpus 72.5%/0.789, batch worksheet 0 raised/0 diverge,
000565 e2e 11/11, suite 2987 passed (2 known pre-existing fails). pyright not
installed in this container — strict type gate not run locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 09:58:02 +00:00
..
applications put db engine construction inside handler to avoid import errors in test 2026-06-09 15:18:42 +00:00
datatypes fix(mapper): map truncated Elmhurst glazing label "Double between 2002" (RdSAP 10 Table 24 code 3) 2026-06-21 06:15:25 +00:00
domain fix(tariff): Unknown meter + dual electric immersion → off-peak per §12 (RdSAP 10 PDF p.62) 2026-06-23 09:58:02 +00:00
e2e Prove prediction resolves landlord overrides to a real cohort match end-to-end 🟩 2026-06-16 15:20:49 +00:00
fixtures/epc_prediction feat(epc-prediction): geo-proximity weighting, per-component (#1227) 2026-06-15 14:58:42 +00:00
harness feat(modelling): drive measure scoping from the Scenario's exclusions 2026-06-16 15:26:25 +00:00
infrastructure fix(fuel): cost main heating system 2 at its own fuel price, not main 1's (SAP 10.2 §10a worksheet line 213) 2026-06-23 08:31:04 +00:00
magic_plan Migrate all MagicPlan tests to single new-format fixture 🟪 2026-06-05 12:59:56 +00:00
orchestration feat(modelling): mark a Property as run via has_recommendations + updated_at 2026-06-16 23:34:33 +00:00
repositories Overlay landlord property-type and built-form corrections onto the Effective EPC 🟩 2026-06-17 18:06:29 +00:00
scripts fix terraform error and pass handler bool for dry runs 2026-06-15 14:06:54 +00:00
utilities added floats helper 2026-06-12 14:28:41 +00:00
__init__.py added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
conftest.py Audit generator populates XLSX, uploads to S3, and records UploadedFile row 🟪 2026-06-09 12:05:55 +00:00
test_lambda_packaging.py better smoke tests to check what is failign 2026-06-17 11:53:33 +00:00