SAP 10.2 Appendix N2 (PDF p.101, footnote 44/45): for an air/ground/water source heat pump whose plant size ratio exceeds the record's largest PSR, the efficiency is reciprocal-interpolated between the largest-PSR value and 100% at twice the largest PSR (100% beyond that); below the smallest PSR the efficiency is 100%. Our interpolator instead clamps to the top/bottom row. Anchored to the accredited Elmhurst worksheet for cert 100110101713 (golden fixture case 56, PCDB 100061): PSR 3.10665 over the record's largest 2.0 gives eta_space,1 = 147.011 -> (206) = 0.95 x 147.011 = 139.660, vs the clamped 352.0 -> 334.4% that over-rates the dwelling by +18 SAP. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com> |
||
|---|---|---|
| .. | ||