Khalim Conn-Kowlessar 23aaa4fa66 Slice S0380.93: floor above partially-heated space U=0.7 (RdSAP 10 §5.14)
RdSAP 10 §5.14 (PDF p.47) "U-value of floor above a partially heated
space":

> "The U-value of a floor above partially heated premises is taken as
>  0.7 W/m²K. This applies typically for a flat above non-domestic
>  premises that are not heated to the same extent or duration as the
>  flat."

Cert 000565 Ext1 lodges Summary §9 "Location: P Above partially
heated space" + "Default U-value: 0.70". Worksheet line (28b) confirms
"Exposed floor Ext1 ... 34.0000 0.7000 23.8000".

Pre-slice the cascade routed BP[1] floor through the BS EN ISO 13370
ground-floor formula (the "else" branch of the floor U-value dispatch
in `heat_transmission.py`) — producing cascade U=0.76 vs spec 0.70.
Over-counted floor heat loss by (0.76 − 0.70) × 34 m² = +2.04 W/K on
the part subtotal and on the total HTC.

Slice span (4 layers):
1. **Helper** — `u_floor_above_partially_heated_space()` in
   `domain/sap10_ml/rdsap_uvalues.py`, verbatim spec constant 0.7
   (no age-band / insulation-thickness inputs). Lives in `sap10_ml`
   per [[project-sap10_ml-deprecation]] (edit existing file fine).
2. **Schema** — `SapFloorDimension.is_above_partially_heated_space:
   bool = False` (parallel to existing `is_exposed_floor`). Mutually
   exclusive with the exposed-floor / basement-floor branches.
3. **Mapper** — new `_is_floor_above_partially_heated_space(location)`
   helper detecting "above partially heated" in the Elmhurst §9 floor
   location string. Plumbed into `_map_elmhurst_building_part` floor-
   dim construction; only applies to the ground floor (i==0).
4. **Cascade** — `heat_transmission.py` adds a new branch between
   the exposed-floor and ground-floor branches: `is_above_partial →
   u_floor_above_partially_heated_space()`.

Cert 000565 movement (HEAD `a7894b11` → this slice):
  - cascade floor_w_per_k:    72.41 → 70.37 (Δ +10.74 → Δ +8.70)
  - cascade BP[1] floor U:    0.76  → 0.70  (✓ EXACT vs ws 0.70)
  - sap_score (integer):      29 ✓ EXACT (unchanged — at goal)
  - sap_score_continuous:     28.7663 → 28.8131 (+0.0468 drift)
  - space_heating_kwh:        −367 → −427 (small drift further under)
  - main_heating_fuel:        −216 → −251 (downstream of SH)
  - co2_kg_per_yr:            −32   → −37
  - total_fuel_cost_gbp:      −23   → −27
  - hot_water_kwh:            ✓ 0 EXACT unchanged

The small continuous-SAP drift is the expected arithmetic of closing
a single component when adjacent components remain unclosed (floor
+10.74 was cancelling thermal_bridging −11.76 + roof −7.94 at the
net-HTC level). Per [[feedback-zero-error-strict]] + [[feedback-
spec-citation-in-commits]] the spec-correct slice ships regardless
of transient continuous-SAP drift; remaining residual components
(floor +8.70 from BP[2] Ext2 lodged 200 mm insulation thickness;
roof −7.94; thermal_bridging −11.76; walls −1.67) each get their own
spec-cited slice.

Cohort safety: only cert 000565 Ext1 in the cohort lodges "Above
partially heated space". All other Elmhurst cohort fixtures + 9
golden + 38 cohort-2 API certs default to `is_above_partially_
heated_space=False` so cascade behaviour is unchanged.

Test baseline: 583 pass + 8 expected `000565` fails (was 582 + 8;
+1 new mapper-chain test). Pyright net-zero per touched file
(1/65/1/32/13/13 preserved).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-05-30 13:53:28 +00:00
..
fixtures Slice S0380.52: cert 000565 Elmhurst-only mapper-driven cascade pin + glazing-label coverage 2026-05-28 22:03:52 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
test_elmhurst_extractor.py extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_summary_pdf_mapper_chain.py Slice S0380.93: floor above partially-heated space U=0.7 (RdSAP 10 §5.14) 2026-05-30 13:53:28 +00:00