Khalim Conn-Kowlessar 23e35da614 Slice 101c: HP cert 0380 — Table 4f cat-4 pumps/fans = 0
SAP 10.2 Table 4f lists annual pumps + fans electricity consumption
by main heating category. The cascade's
`_PUMPS_FANS_KWH_BY_MAIN_CATEGORY` only had cat-2 (gas-fired
boilers, 160 kWh = 115 pump + 45 flue fan) — HP certs (cat 4) fell
through to the 130 kWh/yr DEFAULT.

Heat pumps have NO additional pumps/fans contribution per Table 4f:
the HP system's circulation pump + fans are already incorporated
into the seasonal COP. Worksheet line (249) "Pumps, fans and
electric keep-hot" shows 0.0000 kWh for cert 0380 (ASHP).

Added `4: 0.0`. Effect on cert 0380 API path: pumps_fans cost
£17.15 → £0.00 (matches worksheet); total cost £171.36 → £154.21
(worksheet £206.75; remaining Δ -£52 is dominated by the hot-water
cascade gap which is the next slice — cylinder storage + primary
loss + HP HW COP + separate electric shower line all need work).

No golden cert residual shifts (cohort certs are all gas boilers).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:45 +00:00
..
addresses standardist Address 2026-05-22 10:13:32 +00:00
data_transformation moved classifier data transformation to an easy one 2026-06-01 14:53:34 +00:00
epc pr review, move domain and orhcestration 2026-06-01 14:00:31 +00:00
sap10_calculator Slice 101c: HP cert 0380 — Table 4f cat-4 pumps/fans = 0 2026-06-01 16:28:45 +00:00
sap10_ml Slice 101b: HP cert 0380 — cavity+EWI wall U + Table 11 cat-4 secondary 2026-06-01 16:28:45 +00:00
tasks added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
postcode.py get rid of comments 2026-05-20 13:21:11 +00:00