When a property failed, the handler recorded only its bare property_id and
raised RuntimeError("failed property_ids: [...]"). That string is what
SubTask.fail persists into the subtask outputs.error column, so a failed run
told you which property failed but never why — forcing a CloudWatch lookup.
The per-property catch now captures property_id, uprn, error_type, and the
error message, and the raised RuntimeError embeds those as JSON so the subtask
outputs column is parseable directly. query_failed_modelling_e2e.py reads that
outputs.error into a new Error column in its report.