Khalim Conn-Kowlessar 2a4d67e396 feat(conservatory): §6.1 solar gains + TFA-occupancy (demand-side)
Close the §6.1 conservatory demand cascade per RdSAP 10 §6.1 + Table 25.

Solar gains (§6, solar_gains.py) — Table 25 note (PDF p.51): "The
orientation of windows in a conservatory is not recorded, thus solar
gains are calculated using the default solar flux (East/West orientation,
with 20° pitch for roof windows)." The glazed wall bills onto the (76)
East line (vertical, average-overshading Z); the glazed roof onto the
(82) roof-window line (20° pitch, Z=1.0), both at Table 25 g=0.76, FF=0.70.

TFA-occupancy (mapper) — §6.1: the conservatory floor area is added to the
dwelling total floor area. TFA drives occupancy → §5 internal gains + §4
hot-water demand, so the non-separated conservatory's floor area now
enters `EpcPropertyData.total_floor_area_m2` (the worksheet's (4) = 95.38
carries it). Separated conservatories (§6.2) stay excluded.

Pinned against the case-44 P960 demand cascade at abs=1e-4: (73) internal
gains 625.1759, (83) solar gains 495.8655, (95) useful gains 1079.6510,
(99) space heating per m² 89.8073 — the full §6.1 chain reproduces EXACTLY.

The whole-dwelling SAP (72.9517) / CO2 (3241.8656) are not pinned: the
case-44 Summary omits the House-Coal secondary heater (SAP 633) the P960
descriptor carries (cf. case 43), so the cascade computes no secondary —
the entire residual (+349.77 kg CO2). A Summary-input defect, independent
of §6.1; every conservatory-affected line ref is exact. Worksheet harness
stays 47/47 0-raised; corpus unchanged (API path; mirror is the next slice).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 23:21:08 +00:00
..
domain feat(conservatory): §6.1 solar gains + TFA-occupancy (demand-side) 2026-06-16 23:21:08 +00:00
loaders demo generated for use in address2uprn 2026-05-08 14:48:15 +00:00
schema fix(mapper): map dropped §3.9.2 Simplified Type-2 room-in-roof (API) 2026-06-16 15:01:11 +00:00
search bolstering testing 2026-04-28 13:46:09 +00:00
surveys fix(ventilation): read Blower Door AP50 pressure test (Summary) 2026-06-16 23:18:17 +00:00
__init__.py testing out rebaselining 2026-02-12 22:25:03 +00:00
construction_age_band.py testing out rebaselining 2026-02-12 22:25:03 +00:00
efficiency.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
floor.py preparing partiy class 2026-02-05 08:54:27 +00:00
fuel.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
heating_controls.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
hotwater.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
main_heating.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
property_type_built_form.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
roof.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
walls.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
windows.py testing out rebaselining 2026-02-12 22:25:03 +00:00