When DHW is heated by the main heat pump (WHC 901/902/914 = "from main
system") and the main carries a PCDB Table 362 record,
`_hot_water_fuel_cost_gbp_per_kwh` billed the electric HW at 100% off-peak
low rate (its long-standing TODO). SAP 10.2 Table 12a Grid 1 WH column
(PDF p.191) puts HP-DHW on the ASHP/GSHP-from-database row: 0.70
high-rate fraction at 7-hour and 10-hour → 0.70×14.68 + 0.30×7.50 =
12.526 p/kWh (10-hour), not 7.50 p. The low-rate collapse over-credited
the cat-4 HP-DHW cluster.
Fix: pass the cert WHC into the helper and, for HP-DHW (WHC ∈ {901,902,
914} + PCDB-HP main), bill at the ASHP_APP_N WH blended rate. Electric
IMMERSION (WHC 903) is a different Table 12a row (off-peak immersion 0.17
/ Table 13) and stays on the 100%-low-rate fallback until that slice
lands.
cat-4 cluster (20 certs): mean|err| 2.43→2.11, mean signed +0.06→-0.52
(now per-cert scatter, no systematic bias); cert 9472 +6.4→+3.2, 2789
+6.8→+4.0, 4135 +2.7→within 0.5. Headline mean|err| 1.727→1.720.
Regression green (2447 pass incl. golden 6035 + ASHP cohort at 1e-4);
pyright net-zero.