SAP 10.2 Appendix N3.5 (PDF p.106-107) replaces Table 9c steps 3-4
for heat-pump packages with PCDB data — each month blends the
heating temperature Th, the unimodal (16-hour day, one 8-hour off
period per Table N7 footnote b) zone temperature, and the bimodal
(9-hour day, two off periods per Table N7) zone temperature via
Equation N5:
T = [N24,9 × Th + N16,9 × T_uni + (Nm − N16,9 − N24,9) × T_bi] / Nm
`mean_internal_temperature_monthly` gains an optional
`extended_heating_days_per_month` kwarg (12-tuple of (N24,9_m,
N16,9_m)). When provided, the orchestrator computes T_unimodal per
zone from a single 8-hour off-period reduction and blends; when
None (default — every non-HP cert) it returns T_bimodal directly,
so closed certs (001479, 0330, 9501) are bit-identical.
`cert_to_inputs` derives the per-month tuple for HP certs with PCDB
records carrying `heating_duration_code = "V"` (Variable) — the
only code lodged on modern records per SAP 10.2 PDF p.105 footnote
48. Cohort path: PSR (= max_output_kw × 1000 / (HLC × 24.2 K)) →
Table N5 PSR interpolation → cold-first day allocation. Fixed
durations "24" / "16" / "9" from legacy Table N4 are deferred —
not exercised by the cohort.
Cert 0380 SAP residual closes from +0.5999 → +0.1550 vs worksheet
88.5104. The remaining ~0.16 SAP delta is split between two
orthogonal §5 / §7 residuals (cold-month +0.008°C MIT drift from
spurious HP pump gains; sub-1e-3 efficiency bias) that the next
slices target. Pin tolerance is 1e-2 per month on worksheet (92)
to capture this slice's contract alone, with `feedback_zero_error_
strict` widening documented inline.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||
| handler | ||
| tests | ||
| __init__.py | ||
| db_writer.py | ||
| elmhurst_extractor.py | ||
| extractor.py | ||
| local_runner.py | ||
| parser.py | ||
| pdf.py | ||