Model/datatypes/epc/domain
Khalim Conn-Kowlessar 24492aa4ba Merge origin/main into feature/bill-derivation (calculator + mapper fixes)
Pulls in 42 commits of calculator/mapper accuracy fixes from the per-cert
mapper-validation and floor/roof/heating fronts.

Conflict resolutions:
- mapper `_is_elmhurst_roof_window`: main dropped the branch's "wall location →
  vertical" guard (it broke cert 000516's rooflight), but that re-broke cert
  001431's two External-wall U>3.0 windows (which must stay vertical). The two
  certs lodge a BYTE-IDENTICAL §11 row, so neither location nor U separates
  them — the real discriminator is the room-in-roof context. Replaced the
  unconditional U>3.0 backstop with one gated on the BP having a room-in-roof
  (`_elmhurst_bp_has_room_in_roof`): 000516's Main BP has a "Room in roof type
  1" (→ rooflight), 001431's does not (→ vertical). Validated against BOTH —
  full Elmhurst worksheet suite 1038 pass + the 001431 window-extraction pin.
- property_postgres_repository: kept main's `ids_by_uprn` method + the branch's
  `_restrictions_of` helper.
- sap_fuel.py: the branch relocated it to domain/billing/ (already carrying
  main's to_table_32_code normalization), so kept the old path deleted.

Fallout from main's fabric fixes (validated by the boiler-3 real-cert pin which
still reproduces at delta 0):
- re-pinned the boiler-1 + boiler-instant-hw ASHP snapshot scores;
- main's §14.2 gas-boiler main-fuel derivation resolved the BGB/102 baseline
  gap, so `test_gas_boiler_instant_hw_before_baselines` is now a passing test
  (was an xfail tripwire).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 13:12:21 +00:00
..
tests fix(floor): floor_heat_loss=3 → above partially heated space, U=0.7 (RdSAP §3.12) 2026-06-07 22:25:04 +00:00
__init__.py fix broken imports and rename mapper class 2026-04-13 16:36:13 +00:00
epc.py feat(modelling): Epc.sap_lower_bound() — band → minimum SAP (#1160) 2026-06-03 12:50:40 +00:00
epc_codes.csv slice 8a: window physics and orientation aggregates 2026-05-16 15:32:45 +00:00
epc_property_data.py Merge remote-tracking branch 'origin/main' into feature/bill-derivation 2026-06-05 11:09:00 +00:00
field_mappings.py insulation thickness can be string 🟥 2026-04-15 14:26:09 +00:00
historic_epc.py demo generated for use in address2uprn 2026-05-08 14:48:15 +00:00
historic_epc_matching.py rank address similiarity 2026-05-12 16:02:01 +00:00
mapper.py Merge origin/main into feature/bill-derivation (calculator + mapper fixes) 2026-06-08 13:12:21 +00:00