Model/datatypes/epc/domain
Khalim Conn-Kowlessar 2f5ca85854 S0380.215: capture dropped measured wall insulation thickness
The schema-21 SapBuildingPart never declared `wall_insulation_thickness_
measured`, so `from_dict` silently discarded it. When a cert lodges
`wall_insulation_thickness == "measured"` the actual value (mm) lives in
that dropped field, so the cascade fell back to the 50 mm "insulation
present, unknown thickness" default instead of the lodged measurement.

Cert 2130 Ext1 lodges solid brick band B + INTERNAL insulation
"measured"/100 mm. Per RdSAP 10 §5.7 Table 8 (insulated-wall U by age band
+ insulation thickness) the 100 mm row gives U=0.32; the unknown-thickness
fallback gave 0.55. New `_api_resolve_wall_insulation_thickness` substitutes
the measured value for the "measured" sentinel; the existing
`_insulation_bucket`/Table-8 path then computes the correct U. Field added
to schema 21.0.0/21.0.1 SapBuildingPart; domain field widened to
Union[str, int] to match `roof_insulation_thickness`. Isolated: 2130 Ext1
is the only bp lodging "measured" across all 47 fixtures.

This spec-correct fix EXPOSED an offsetting under-count it had been masking
(per the repo's no-special-handling rule — the pre-fix +1 was two bugs
cancelling): 2130 cont SAP 83.35 → 83.78 (resid +1 → +2), PE -7.56 →
-11.72, CO2 -0.045 → -0.095. The exposed -11.72 PE (~-746 kWh/yr) is the
deferred gas-combi-PE + PV-β-credit under-count from S0380.45/.49, now
un-masked — the next slice. Re-pinned 2130 with the cause documented.

Suite: 2391 passed, 1 skipped. Zero new pyright errors (mapper 32=32).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-04 10:30:49 +00:00
..
tests S0380.215: capture dropped measured wall insulation thickness 2026-06-04 10:30:49 +00:00
__init__.py fix broken imports and rename mapper class 2026-04-13 16:36:13 +00:00
epc.py added ucl corrected peui 2026-05-16 14:39:24 +00:00
epc_codes.csv slice 8a: window physics and orientation aggregates 2026-05-16 15:32:45 +00:00
epc_property_data.py S0380.215: capture dropped measured wall insulation thickness 2026-06-04 10:30:49 +00:00
field_mappings.py insulation thickness can be string 🟥 2026-04-15 14:26:09 +00:00
historic_epc.py demo generated for use in address2uprn 2026-05-08 14:48:15 +00:00
historic_epc_matching.py rank address similiarity 2026-05-12 16:02:01 +00:00
mapper.py S0380.215: capture dropped measured wall insulation thickness 2026-06-04 10:30:49 +00:00