Khalim Conn-Kowlessar 2f92edb050 Slice S0380.8: extension 'As Main Wall' inheritance copies insulation_thickness_mm
Regression fix surfaced by the first-attempt cert 0350 prediction
test. `_extract_extensions` in `backend/documents_parser/elmhurst_
extractor.py` builds a synthetic `WallDetails` for any extension
that lodges "As Main Wall: Yes" (copying the Main bp's wall fields
so the cascade gets the same wall config for the extension). Slice
S0380.4 added a new `insulation_thickness_mm` field to `WallDetails`
but did NOT update the inheritance code at line 559-567 — so any
multi-bp cert with an "As Main Wall" extension was losing the lodged
wall insulation thickness on its extension bps, regardless of cert.

Cert 0350-2968-2650-2796-5255 is the first multi-bp ASHP cohort cert
through the Summary path (Main + 1st Extension, both "CA Cavity / FE
Filled Cavity + External / 100 mm"). The dr87 worksheet line ref
(29a) lodges:
  Main: 19.4575 W/K  (77.83 m² × 0.25 W/m²K)
  Ext1:  1.3025 W/K  ( 5.21 m² × 0.25 W/m²K)
  total: 20.7600 W/K
Pre-fix Summary cascade produced walls_w_per_k 22.2188 (over by
+1.46 W/K) because Ext1's missing thickness defaulted to a higher
U-value path. Post-fix walls_w_per_k = **20.7600 — exact match
against worksheet (29a) sum**.

One-line fix at `elmhurst_extractor.py:567`:
+ insulation_thickness_mm=main_walls.insulation_thickness_mm,

Forcing function: cert 0350 first-attempt SAP moves from Δ -4.7365
to Δ -4.5829 — small +0.1536 SAP gain from walls alone. The
remaining ~-4.58 SAP residual on cert 0350 has other contributors
to investigate in subsequent slices (HW kWh 1206 vs predicted target,
HTC 173.42 vs worksheet (39) avg — likely floor / ventilation / PV
gaps not yet covered by Summary mapper).

Added focused unit test
`test_summary_0350_ext1_inherits_main_wall_insulation_thickness`
that pins the inheritance contract directly on the mapper boundary
(bp[0].wall_insulation_thickness == bp[1].wall_insulation_thickness
== "100mm"). Will fail if a future field-addition to WallDetails
again forgets to update the synthetic-WallDetails inheritance block.

Pyright net-zero across both edited files.

Regression suite: 676 pass + 10 fail (= handover baseline 669 + 10
+ 7 new GREEN unit tests across Slices S0380.2..S0380.8).

Spec / cohort context:
- Affects ALL multi-bp Elmhurst Summary certs with "As Main Wall:
  Yes" extensions, not just cert 0350. None of the previously-
  closed cohort certs (001479, 0330) exercised this path — both
  single-bp dwellings.
- SAP 10.2 §3.7 / Table S5 — composite filled-cavity-plus-external
  U-value calc, keyed on lodged insulation thickness.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:46 +00:00
..
handler address JTK review comments 2026-04-20 15:11:17 +00:00
tests Slice S0380.8: extension 'As Main Wall' inheritance copies insulation_thickness_mm 2026-06-01 16:28:46 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
db_writer.py include updating epc_property_data to pashub to ara workflow 2026-04-29 09:55:14 +00:00
elmhurst_extractor.py Slice S0380.8: extension 'As Main Wall' inheritance copies insulation_thickness_mm 2026-06-01 16:28:46 +00:00
extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
local_runner.py update local runner to work for elmhurst 2026-04-24 14:01:36 +00:00
parser.py load ecmk site notes to db 2026-04-29 11:20:47 +00:00
pdf.py update local runner to work for elmhurst 2026-04-24 14:01:36 +00:00