Jun-te Kim 3282cef04e Fix RdSAP-17.0 mapper dropping lodged secondary heating
The `from_rdsap_schema_17_0` path hardcoded `sap_heating.secondary_heating_type`
and `secondary_fuel_type` to None, unlike every other API path (19.0/20.0/…),
which read them from `schema.sap_heating`. The gov EPC API *does* populate a
secondary heating SAP code for a genuine fixed secondary (e.g. 691 "electric
room heaters", 694), so the hardcode silently discarded it.

Because `recommend_secondary_heating_removal` gates purely on
`sap_heating.secondary_heating_type`, any 17.0 cert carrying a fixed secondary
would never get its removal recommendation. Surfaced while auditing portfolio
814's recommendations; 814 has 17.0 certs but none with a fixed secondary, so
the defect was latent there — this restores parity with the other paths so it
cannot bite.

Mirrors the 19.0 path exactly (secondary_fuel_type via `_api_secondary_fuel_type`).
Adds a regression guard that injects a fixed secondary into a real 17.0 cert and
asserts the code survives the mapping.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-01 10:41:52 +00:00
..
epc Fix RdSAP-17.0 mapper dropping lodged secondary heating 2026-07-01 10:41:52 +00:00
__init__.py further breaking up code 2023-07-20 12:24:34 +01:00
datatypes.py further breaking up code 2023-07-20 12:24:34 +01:00
enums.py completed build of new demo portfolio - some fixed required still 2023-11-20 14:42:16 +00:00