RdSAP 10 Specification §3.10.1 (PDF p.24) "Default U-values of the
roof rooms":
"Where the details of insulation are not available, the default
U-values are those for the appropriate age band for the
construction of the roof rooms (see Table 18 : Assumed roof
U-values when Table 16 or Table 17 do not apply). The default
U-values apply when the roof room insulation is 'as built' or
'unknown'."
Cert 000565 Summary §8.1 BP[4] Ext4 lodges:
Flat Ceiling 1 5.00 1.00 Unknown PUR or PIR 0.15 No
Worksheet line (30): `Roof room Ext4 Flat Ceiling 1: 5 × 0.15 =
0.75 W/K` (U985-0001-000565 line 333).
Pre-slice the extractor allow-list `_RIR_INSULATION_THICKNESS_RE
| ("As Built", "None")` did NOT include the "Unknown" thickness
token, so the cell was dropped (`insulation = ""`). The mapper
translated `""` to `insulation_thickness_mm=0`, and the cascade
hit Table 17 row 0 → U=2.30 vs worksheet 0.15 (over-counting
BP[4] FC1 by +10.75 W/K on a 5 m² ceiling).
Two-layer fix:
1. Extractor (`elmhurst_extractor.py:_parse_rir_surface_row`) — add
"Unknown" as the third spec-valid thickness token alongside
"As Built" and "None".
2. Mapper (`mapper.py:_elmhurst_rir_insulation_thickness_mm`) —
return `Optional[int]`; "Unknown" → None. The cascade's existing
`_u_rr_table_17` already falls back to `u_rr_default_all_elements`
(Table 18 col 4) when thickness is None — for cert 000565 BP[4]
age band M, returns 0.15 W/m²K ✓.
Cascade no-op: the existing None → Table 18 col 4 fallback IS the
spec-correct path per §3.10.1; no calculator changes needed.
Movement at HEAD (cert 000565):
- BP[4] FC1 cascade U: 2.30 → 0.15 ✓ EXACT vs ws 0.15
- roof_w_per_k: 63.72 → 52.97 (Δ +12.34 → +1.59, closed -10.75)
- sap_score_continuous: 28.07 → 28.31 (Δ -0.44 → -0.20)
- sap_score (int): 28 (continuous still below 28.5 threshold;
remaining residual + BP[1] residual + BP[2] floor)
- SH: +533 → +218 kWh
Test count: 585 → 587 pass (+2 new AAA tests) + 9 expected 000565
fails unchanged.
Cohort safety: "Unknown" RIR insulation appears only in cert 000565
across the Summary fixture set (grep audit); cohort certs lodge
concrete thickness or "None"/"As Built". Pyright net-zero per
touched file.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||
| handler | ||
| tests | ||
| __init__.py | ||
| db_writer.py | ||
| elmhurst_extractor.py | ||
| extractor.py | ||
| local_runner.py | ||
| parser.py | ||
| pdf.py | ||