Elmhurst §14.0 leaves "Fuel Type" empty for electric main heating
systems (heat pumps, electric boilers, storage heaters, electric
underfloor, warm-air HPs) — the SAP code identifies the carrier
directly. The mapper was reading the empty string via
`_elmhurst_main_fuel_int(mh.fuel_type)` → None, and downstream
`_main_fuel_code` returned None, so Table 32 unit-price lookups
defaulted to mains gas. Cert 000565 (HP Main 1, SAP code 224) was
being charged 29,353 kWh/yr of electricity at the gas tariff —
£0.0364/kWh instead of £0.165/kWh.
New `_ELECTRIC_SAP_MAIN_HEATING_CODES` frozen set covers the Table
4a electric carrier rows:
191-196 Electric boilers
211-217, 221-227 Heat pumps (224 = ASHP 2013+, 1.70 COP)
401-409 Electric storage heaters
421-425 Electric underfloor heating
521-527 Warm-air heat pumps
Inference fires in both Main 1 (`_map_elmhurst_sap_heating`) and
Main 2 (`_map_elmhurst_main_heating_2`) construction paths — when
`_elmhurst_main_fuel_int(fuel_type)` returns None AND the SAP code
is in the electric set, fall back to `_STANDARD_ELECTRICITY_FUEL_
CODE = 30` (Table 12 row "Electricity, standard tariff").
Cert 000565 cascade impact (compounding with S0380.56):
- sap_score: 71 → 30 (target 29 → Δ +1.7; was Δ +44)
- sap_score_continuous: 71.42 → 30.21 (target 28.51 → Δ +1.70; was Δ +42.91)
- ecf: 2.05 → 5.22 (target 5.39 → Δ −0.17; was Δ −3.34)
- total_fuel_cost_gbp: 1,423.80 → 3,624.64 (target 4,680.26 → Δ −1,055.62; was Δ −3,256.46)
- co2_kg_per_yr: 7,181.62 → 5,009.47 (target 6,447.63 → Δ −1,438.16; was Δ +733.99)
(now undershooting — independent cascade gap
around Table 12d monthly electric CO2 factor
interpolation; separate slice)
Single-main non-HP certs: no behavioural change (`fuel_type` lodged
explicitly for gas/oil boilers → `_elmhurst_main_fuel_int` returns
non-None → inference branch not entered). Cohort regression check:
472 pass + 10 expected 000565 fails — no regression.
Spec source: SAP 10.2 Table 4a main heating SAP codes + Table 12 fuel
codes (electricity, standard tariff = 30). Heat-pump cohort efficiency
values cross-referenced in `domain/sap10_ml/sap_efficiencies.py:42-44`.
Pyright net-zero on mapper.py (32 / 32).