"""The Landlord-Override glazing → glazing Simulation Overlay mapping.
|
|
|
|
A glazing value resolves to the SAP10 `glazing_type` code the calculator's
|
|
Table-24 cascade reads; the overlay is whole-dwelling (expanded across every
|
|
window by `_fold_glazing`).
|
|
"""
|
|
|
|
from __future__ import annotations
|
|
|
|
import pytest
|
|
|
|
from domain.epc.property_overrides.glazing_type import GlazingType
|
|
from domain.epc.property_overlays.glazing_overlay import glazing_overlay_for
|
|
from domain.modelling.scoring.overlay_applicator import apply_simulations
|
|
from tests.domain.sap10_calculator.worksheet._elmhurst_worksheet_000490 import (
|
|
build_epc,
|
|
)
|
|
|
|
|
|
def test_double_glazing_post_2002_overlays_its_glazing_code() -> None:
|
|
# Act
|
|
simulation = glazing_overlay_for("Double glazing, 2002 or later", 0)
|
|
|
|
# Assert — double glazing 2002-2021 is SAP10 glazing_type code 2.
|
|
assert simulation is not None
|
|
assert simulation.glazing is not None
|
|
assert simulation.glazing.glazing_type == 2
|
|
|
|
|
|
@pytest.mark.parametrize(
|
|
("glazing_value", "code"),
|
|
[
|
|
("Single glazing", 1),
|
|
("Double glazing, pre-2002", 3),
|
|
("Triple glazing, 2002 or later", 9),
|
|
("Triple glazing, pre-2002", 6),
|
|
],
|
|
)
|
|
def test_glazing_types_decode_to_their_sap_codes(
|
|
glazing_value: str, code: int
|
|
) -> None:
|
|
# Act
|
|
simulation = glazing_overlay_for(glazing_value, 0)
|
|
|
|
# Assert
|
|
assert simulation is not None
|
|
assert simulation.glazing is not None
|
|
assert simulation.glazing.glazing_type == code
|
|
|
|
|
|
@pytest.mark.parametrize("glazing_value", ["Unknown", ""])
|
|
def test_unresolvable_glazing_produces_no_overlay(glazing_value: str) -> None:
|
|
# Act
|
|
simulation = glazing_overlay_for(glazing_value, 0)
|
|
|
|
# Assert
|
|
assert simulation is None
|
|
|
|
|
|
def test_glazing_override_remaps_every_window_and_clears_lodged_u() -> None:
|
|
# Arrange — baseline windows are double glazed (code 2, lodged U 2.8); the
|
|
# landlord corrects the whole dwelling to single glazing.
|
|
baseline = build_epc()
|
|
assert len(baseline.sap_windows) > 1
|
|
overlay = glazing_overlay_for("Single glazing", 0)
|
|
assert overlay is not None
|
|
|
|
# Act
|
|
result = apply_simulations(baseline, [overlay])
|
|
|
|
# Assert — every window flips to single (code 1) and its lodged transmission
|
|
# U is cleared so the Table-24 cascade re-derives U from the new type.
|
|
assert all(w.glazing_type == 1 for w in result.sap_windows)
|
|
assert all(w.window_transmission_details is None for w in result.sap_windows)
|
|
|
|
|
|
@pytest.mark.parametrize(
|
|
"member", [m for m in GlazingType if m is not GlazingType.UNKNOWN]
|
|
)
|
|
def test_every_resolvable_glazing_value_decodes_to_a_code(
|
|
member: GlazingType,
|
|
) -> None:
|
|
# A classifier emits a GlazingType value; if the overlay can't decode it the
|
|
# override silently no-ops. Every non-UNKNOWN member must resolve.
|
|
|
|
# Act
|
|
simulation = glazing_overlay_for(member.value, 0)
|
|
|
|
# Assert
|
|
assert simulation is not None
|