SAP 10.2 §9.4.9 (PDF p.32) verbatim: "A cylinder thermostat should be
assumed to be present when the domestic hot water is obtained from a heat
network, an immersion heater, a thermal store, a combi boiler or a CPSU."
RdSAP 10 Table 29 (p.56) points the no-access default at this rule.
The storage-loss Table 2b temperature factor previously read only the
lodged `cylinder_thermostat` ("Y") — so an unlodged thermostat always took
the ×1.3 absent-penalty, over-stating storage loss by 30%. New
`_cylinder_thermostat_present` assumes it present when DHW is from a heat
network, WHC 903 (immersion), or a direct-acting electric boiler (SAP code
191 — electric-resistance, immersion-equivalent).
Found via the worksheet-folder harness: cert 2474-3059-4202-4496-3200
(Summary path: WHC 901, main SAP 191, electric, no lodged cylinder stat)
diverged −1.86 from its dr87 worksheet. The worksheet lodges (53)
temperature factor 0.6000 (present) and "add cylinder thermostat (SAP
increase too small)" — already assumed present. Fix lands HW output (64)
2701.99 → 2323.88, EXACT to the worksheet; 2474 −1.86 → −0.87 (residual is
a separate space-demand fabric thread). No other worksheet in the 47-cert
harness moved.
API eval within-0.5 56.9% → 57.6%; mean|err| 1.197 → 1.185; signed
−0.202 → −0.165. Regression green (only pre-existing fails); goldens +
heating corpus unaffected.