Khalim Conn-Kowlessar ca6a0efd70 Slice S0380.155: SAP 10.2 Table 4a — heat-pump water-efficiency column dispatch
SAP 10.2 Table 4a (PDF p.163-164) heat-pump rows split efficiency into
two columns — "space" and "water":

    Code  System                                            space  water
    211   Ground source HP with flow temp <= 35°C            230    170
    213   Water source HP with flow temp <= 35°C             230    170
    215   Gas-fired GSHP with flow temp <= 35°C              120     84
    216   Gas-fired WSHP with flow temp <= 35°C              120     84
    217   Gas-fired ASHP with flow temp <= 35°C              110     77
    521   Warm-air electric GSHP                             230    170
    523   Warm-air electric WSHP                             230    170
    525   Warm-air gas-fired GSHP                            120     84
    526   Warm-air gas-fired WSHP                            120     84
    527   Warm-air gas-fired ASHP                            110     77

The split reflects real physics: heat pumps lose efficiency raising
water to ~55°C DHW temperatures vs ~35°C space-heating flow. ASHP
"in other cases" (codes 214, 221, 223, 224) and the "other cases"
gas-fired rows (225-227) have space == water = 170 / 84 / 77 — no
distinct DHW column.

Pre-slice the cascade routed WHC ∈ {901, 902, 914} ("HW from main
heating") through `seasonal_efficiency(main_code)`, which only consults
the Space column. For SAP code 211 the cascade returned 2.30 (= space)
when the spec requires 1.70 (= water). HW fuel kWh undercounted by
26% on the heating-systems corpus gshp variant: cascade 841.47 kWh vs
worksheet 1138.46 kWh.

New `_TABLE_4A_HEAT_PUMP_WATER_EFFICIENCY` dict (10 codes where Space
≠ Water) consulted in `_water_efficiency_with_category_inherit` before
falling through to the existing `seasonal_efficiency` path. Codes
where Space == Water keep the legacy inheritance — no behaviour
change. Non-HP main heating (boilers, storage heaters) likewise
unchanged.

Closures (gshp variant — SAP code 211 + WHC=901 + cylinder):
  HW fuel kWh:  841.47 → 1138.45 (matches worksheet 1138.46)
  ΔSAP_c:       +0.9373 → -0.0178
  Δcost:        -£21.60 → +£0.41
  ΔCO2:         -34.98  → +7.06 kg/yr
  ΔPE:          -418.92 → +33.52 kWh/yr

No regressions on 40 other corpus variants — gshp is the only fixture
that lodges a heat-pump code with diverging Space/Water columns.

Cohort-1 ASHP closure (S0380.28 reciprocal interpolation) is unaffected
because that path runs through `heat_pump_record` PCDB Appendix N3
when a PCDB Table 362 record is lodged; this fix is the Table 4a
fallback for cases without a PCDB record.

Extended handover suite: 899 pass / 0 fail. Pyright net-zero (43 → 43).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
..
addresses standardist Address 2026-05-22 10:13:32 +00:00
data_transformation moved classifier data transformation to an easy one 2026-06-01 14:53:34 +00:00
epc pr review, move domain and orhcestration 2026-06-01 14:00:31 +00:00
sap10_calculator Slice S0380.155: SAP 10.2 Table 4a — heat-pump water-efficiency column dispatch 2026-06-01 16:28:48 +00:00
sap10_ml Slice S0380.109: Solid brick + insulation via §5.7 Table 13 + §5.8 Table 14 (RdSAP 10) 2026-06-01 16:28:47 +00:00
tasks added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
postcode.py get rid of comments 2026-05-20 13:21:11 +00:00