mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-07-22 08:48:38 +00:00
Electric-tariff cluster investigation. The 112-cert electric-main cohort is mixed-sign within every category/meter - no systematic tariff bias. Root cause of the biggest non-xfail divergences (10012334488 +13.2, 10091578598 +7.81): SAP code 195 = 'Electric water storage boiler' (Table 4a p.170), which SAP 10.2 §12 Rule 2 correctly bills mostly at the 7-hour off-peak rate. Both are pure cost gaps (PE/CO2 match lodged -> demand right); the lodged software over-billed the storage boilers at peak rate. The engine is SPEC-FAITHFUL - matching lodged would tune against §12/Table-4a. Pinned to the spec-faithful engine values. Adds scripts/corpus_1000/elec_cohort.py (electric-main cohort analyzer). Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> |
||
|---|---|---|
| .. | ||
| climate | ||
| rdsap | ||
| validation | ||
| worksheet | ||
| __init__.py | ||
| test_bre_worked_examples.py | ||
| test_calculator.py | ||
| test_pcdb_etl.py | ||
| test_pcdb_lookup.py | ||
| test_pcdb_table_322_lookup.py | ||
| test_pcdb_table_323_lookup.py | ||
| test_pcdb_table_329_lookup.py | ||
| test_pcdb_table_362_lookup.py | ||
| test_postcode_weather.py | ||
| test_real_cert_sap_accuracy.py | ||
| test_table_12.py | ||
| test_table_12a.py | ||
| test_table_13.py | ||
| test_table_32.py | ||