Extends `SapRoomInRoof` with six optional fields capturing the RdSAP10
§3.9.2 Simplified Type 2 lodgement: common_wall_length_m / height_m
plus two gable length/height pairs.
Type 2 fires when `common_wall_height_m` is set and < 1.8 m (otherwise
the space is a separate storey). Geometry per spec page 23:
A_common_wall = L × (0.25 + H)
A_gable = L × (0.25 + H_gable)
− Σ ((H_gable − H_common_wall_i)² / 2)
A_RR_final = A_RR − Σ A_common_wall − Σ A_gable
(− party / sheltered / connected when lodged, future
slice when a fixture exercises them)
Common walls and gables route to walls_w_per_k at U_main_wall (per spec:
"Common wall U-value is inferred from the U-value of the main wall in
the building part below"). A_RR_final routes to roof_w_per_k at
u_rr_default_all_elements (Table 18 col 4).
Synthetic test: 1-storey cavity-uninsulated dwelling at age B + RR
(floor 10 m², common_wall_length 5 m × 1 m height). Pins
walls_w_per_k = 60 × 1.5 + 6.25 × 1.5 = 99.375 W/K and
roof_w_per_k = 30 × 0.40 + 26.025 × 2.30 = 71.857 W/K at abs=0.001.
No production fixture exercises Type 2 yet — synthetic test is the
unit-level guard until a Type 2 cert lands in the corpus.
Reference: RdSAP 10 (10-06-2025) §3.9.2 page 22-23.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||
| domain | ||
| loaders | ||
| schema | ||
| search | ||
| surveys | ||
| __init__.py | ||
| construction_age_band.py | ||
| efficiency.py | ||
| floor.py | ||
| fuel.py | ||
| heating_controls.py | ||
| hotwater.py | ||
| main_heating.py | ||
| property_type_built_form.py | ||
| roof.py | ||
| walls.py | ||
| windows.py | ||