mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
Slice 1 of the glazing generator (ADR-0022). `WindowOverlay` (all-optional partial of one SapWindow) + `EpcSimulation.windows` keyed by sap_windows index. The applicator folds it onto sap_windows[i]: glazing_type flat on the window, u_value/solar_transmittance routed into its WindowTransmissionDetails (created if absent) — the applicator's first nested write, because that's where the calculator reads window heat loss and solar gain. Baseline left unmutated. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
87 lines
3.4 KiB
Python
87 lines
3.4 KiB
Python
"""The Simulation Overlay (`EpcSimulation`) — the change a single Measure
|
|
Option makes to a Property's EpcPropertyData.
|
|
|
|
An all-optional partial mirror of EpcPropertyData / SapBuildingPart, covering
|
|
the retrofit-relevant surface only (wall fields first). It is *not* an
|
|
EpcPropertyData — composition, not inheritance — and carries no scores.
|
|
Building parts are targeted by `BuildingPartIdentifier` so a measure addresses
|
|
the exact `SapBuildingPart` (the main wall vs an extension). See CONTEXT.md.
|
|
"""
|
|
|
|
from dataclasses import dataclass, field
|
|
from typing import Mapping, Optional
|
|
|
|
from datatypes.epc.domain.epc_property_data import BuildingPartIdentifier
|
|
|
|
|
|
@dataclass(frozen=True)
|
|
class BuildingPartOverlay:
|
|
"""All-optional partial of `SapBuildingPart` (wall surface first).
|
|
|
|
A `None` field means "leave the baseline value unchanged".
|
|
"""
|
|
|
|
wall_insulation_type: Optional[int] = None
|
|
# Added solid-wall insulation depth (mm) — drives the calculator's Table 6
|
|
# bucket / §5.8 documentary U-value for EWI (`wall_insulation_type=1`) and
|
|
# IWI (`wall_insulation_type=3`); λ defaults to 0.04 W/m·K in the calculator.
|
|
wall_insulation_thickness: Optional[int] = None
|
|
roof_insulation_thickness: Optional[int] = None
|
|
floor_insulation_thickness: Optional[int] = None
|
|
floor_insulation_type_str: Optional[str] = None
|
|
|
|
|
|
@dataclass(frozen=True)
|
|
class VentilationOverlay:
|
|
"""All-optional partial of `SapVentilation` — the whole-dwelling ventilation
|
|
change a Measure Option makes (e.g. retrofit MEV). Unlike a
|
|
`BuildingPartOverlay` this targets no building part; it folds onto the
|
|
dwelling's single `sap_ventilation`.
|
|
|
|
`mechanical_ventilation_kind` names the SAP10.2 §2 mechanical-ventilation
|
|
kind (the `MechanicalVentilationKind` enum name, e.g.
|
|
``"EXTRACT_OR_PIV_OUTSIDE"`` for decentralised MEV). A `None` field means
|
|
"leave the baseline value unchanged".
|
|
"""
|
|
|
|
mechanical_ventilation_kind: Optional[str] = None
|
|
|
|
|
|
@dataclass(frozen=True)
|
|
class WindowOverlay:
|
|
"""All-optional partial of one `SapWindow` — the change a glazing Measure
|
|
makes to a single window (ADR-0022).
|
|
|
|
`glazing_type` is the SAP10.2 Table U2 code (drives only the §5 daylight
|
|
factor when a per-window U is lodged). `u_value` and `solar_transmittance`
|
|
are written into the window's `WindowTransmissionDetails` — where the
|
|
calculator reads heat loss and solar gain from — because our calculator
|
|
consumes the lodged values directly rather than deriving them from
|
|
`glazing_type`. A `None` field means "leave the baseline value unchanged".
|
|
"""
|
|
|
|
glazing_type: Optional[int] = None
|
|
u_value: Optional[float] = None
|
|
solar_transmittance: Optional[float] = None
|
|
|
|
|
|
def _no_building_parts() -> dict[BuildingPartIdentifier, BuildingPartOverlay]:
|
|
return {}
|
|
|
|
|
|
def _no_windows() -> dict[int, WindowOverlay]:
|
|
return {}
|
|
|
|
|
|
@dataclass(frozen=True)
|
|
class EpcSimulation:
|
|
"""A Simulation Overlay: the per-building-part changes a Measure Option
|
|
makes, keyed by `BuildingPartIdentifier`; per-window changes keyed by the
|
|
`sap_windows` index; plus an optional whole-dwelling `ventilation` change
|
|
(the Measure Dependency surface — ADR-0016)."""
|
|
|
|
building_parts: Mapping[BuildingPartIdentifier, BuildingPartOverlay] = field(
|
|
default_factory=_no_building_parts
|
|
)
|
|
windows: Mapping[int, WindowOverlay] = field(default_factory=_no_windows)
|
|
ventilation: Optional[VentilationOverlay] = None
|