Flat per-dwelling decommission price (sample_catalogue \£250) + 0.25 contingency (covers unknown heater count / hard-wired-vs-plugged / repaint extent). The JSON repo joins the contingency from config, proven by the new repo test. No composite Products machinery — a lodged secondary is one roughly-fixed job, not room-scaled. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
42 lines
1.5 KiB
Python
42 lines
1.5 KiB
Python
"""Per-Measure-Type contingency rates.
|
|
|
|
The one cost component carried separately from a Product's fully-loaded total
|
|
(CONTEXT.md). Mirrors the legacy `recommendations/Costs.py::Costs.CONTINGENCIES`;
|
|
extended as each measure type lands.
|
|
"""
|
|
|
|
_CONTINGENCY_RATES: dict[str, float] = {
|
|
"cavity_wall_insulation": 0.10,
|
|
"loft_insulation": 0.10,
|
|
"sloping_ceiling_insulation": 0.10,
|
|
"flat_roof_insulation": 0.10,
|
|
"suspended_floor_insulation": 0.20,
|
|
"solid_floor_insulation": 0.26,
|
|
"mechanical_ventilation": 0.26,
|
|
"external_wall_insulation": 0.26,
|
|
"internal_wall_insulation": 0.26,
|
|
"double_glazing": 0.15,
|
|
"secondary_glazing": 0.15,
|
|
"low_energy_lighting": 0.26,
|
|
"high_heat_retention_storage_heaters": 0.10,
|
|
"air_source_heat_pump": 0.25,
|
|
"gas_boiler_upgrade": 0.26,
|
|
"system_tune_up": 0.10,
|
|
"system_tune_up_zoned": 0.10,
|
|
"solar_pv": 0.15,
|
|
# Decommissioning a fixed secondary heater + localised making-good is small,
|
|
# uncertain work: the rate covers the unknown heater count / hard-wired vs
|
|
# plugged status / repaint extent (ADR-0028).
|
|
"secondary_heating_removal": 0.25,
|
|
}
|
|
|
|
|
|
def contingency_rate(measure_type: str) -> float:
|
|
"""Return the contingency rate for a Measure Type, raising if unknown
|
|
(strict — do not silently default, per the repo's strict-raise convention)."""
|
|
try:
|
|
return _CONTINGENCY_RATES[measure_type]
|
|
except KeyError as exc:
|
|
raise ValueError(
|
|
f"no contingency rate configured for measure type {measure_type!r}"
|
|
) from exc
|