Model/backend/documents_parser/tests
Khalim Conn-Kowlessar 4a21717de6 S0380.195: pin sim case 4 (6035 floor geometry) e2e at 1e-4 — 6035 +19 PE is lodged divergence
Adds the user-simulated case-4 worksheet as e2e fixture `001431_6035` —
reproduces golden cert 6035's full floor geometry (Main ground-floor HLP
15.99 + first-floor HLP 8.32, the asymmetric upper storey) and 8 windows.
All 11 Block-1 line refs pin at abs=1e-4 against the worksheet (SAP 68,
ECF 2.2802, cost 937.2341, CO2 4682.3494, space 15745.3260, main fuel
18744.4357).

This is the 4th independent 1e-4 confirmation across the 6035 archetype
(sim cases 1-4). Case 4 matches 6035 on floors + window areas; the
residual ~50 kWh / £11 cascade delta vs 6035 is two lodged inputs only
(largest window orientation N vs S; meter type "Dual" vs API 2), not
calculator behaviour.

Conclusion: the cascade reproduces the spec engine exactly for 6035's
geometry, so 6035's +19 PE vs the lodged register is lodged-register
divergence (the gov.uk register's rounded value vs the spec-exact
worksheet), NOT a calculator gap. 6035 is a "pin-forever" lodged-only
cert. Bugs surfaced + fixed along the way: S0380.192 (Simplified-RR
remaining area) and S0380.193 (suspended-floor sealed rule).

2341 passed (+11), 0 failed; pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-03 09:56:39 +00:00
..
fixtures S0380.195: pin sim case 4 (6035 floor geometry) e2e at 1e-4 — 6035 +19 PE is lodged divergence 2026-06-03 09:56:39 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
test_elmhurst_extractor.py fix(extractor): drop windows-table header remnant from first window glazing type 2026-06-02 22:54:49 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_heating_systems_corpus.py S0380.185: record CH6 pin-forever proof — distribution-loss is a Summary-export gap 2026-06-02 19:21:28 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00