SAP 10.2 Appendix N3.1 (PDF p.105) "Circulation pump and fan":
"For electric heat pumps: The electricity used by the water
circulation pump or fan is included within the calculated annual
space and hot water heating efficiency and is not included in
worksheet (230c). **The default heat gain from Table 5a is included
via worksheet (70).**"
This rule applies the Table 5a row "Central heating pump in heated
space" GAIN (3 / 10 / 7 W per pump-age bucket) to electric heat
pumps even though the pump ELECTRICITY is hidden in the COP and
excluded from (230c). The "Not applicable for electric heat pumps
from database" clause in Table 5a footnote a) scopes only to the
PCDB-Table-362 cascade case (Appendix N1.2.1: "For heat pumps held
in the PCDB ... a single water circulation pump serving the heat
emitters is sufficient" — pump kWh AND gain embedded in COP).
S0380.160 over-stripped the gain by zeroing pump_w for every HP
category-4 main, conflating the PCDB-Table-362 case with the Table-4a
default cascade. This slice refines the HP gate in
`_any_main_system_has_central_heating_pump`:
- Cat 4 HP WITH `main_heating_index_number` lodged (PCDB Table
362) → continue (skip; pump in COP per N1.2.1);
- Cat 4 HP with SAP code in `_TABLE_4A_WARM_AIR_SAP_CODES` (Cat 5
warm-air HPs distribute via ducted air, no water circulation
pump; warm-air fan handled separately by Table 5a "Warm air
heating system fans" row, S0380.161) → continue;
- Otherwise (Cat 4 HP, Table 4a default cascade, water-emitter)
→ apply Table 5a default per Appendix N3.1.
Per-line walk on ashp (SAP code 214 air-to-water HP, Cat 4, no PCDB,
"Post 2013" pump age):
worksheet (70)[Jan] = 3.0000 W
cascade pre-slice = 0.0000 W delta = -3.000 W
The -3 W winter gain shortfall over-stated cascade (84) Total gains
by -3 W in heating months → cascade SH demand +12.27 kWh/yr
(cascade 9302 vs worksheet 9290), pushing continuous SAP down 0.024
because the cost residual was driven by the +1.5 kWh × 12 month
shortfall flowing through the £0.0741 low-rate cost.
Closures:
ashp: ΔSAP -0.0240 → +0.0000 EXACT, Δcost +£0.55 → +£0.00 EXACT
gshp: ΔSAP -0.0178 → -0.0000 EXACT, Δcost +£0.41 → -£0.00 EXACT
ΔPE +36 → +25.51 (and ΔCO2 +7.33 → +6.31) — residuals narrow to the
Elmhurst-vs-spec HW PE annual-vs-monthly Table 12e/12d quirk only
(same pattern as the 16-variant lighting-PE deferred cohort,
scaled by HW kWh = 1138 vs 2384 → 25.51 vs 48.66). Cohort
Σ |ΔSAP_c| 0.07 → 0.03; all 25 cascade-OK variants now SAP+cost EXACT.
Cohort-1 (cert 0380 et al.) golden fixtures unaffected — those certs
lodge `main_heating_index_number` (PCDB Table 362) → HP gate skips
correctly → (70) = 0 preserved. Cert 000565 (HP main 1 + gas boiler
main 2) unaffected — wet-boiler branch fires for main 2.
Verbatim spec quote (SAP 10.2 Appendix N3.1, PDF p.105):
"For electric heat pumps: The electricity used by the water
circulation pump or fan is included within the calculated annual
space and hot water heating efficiency and is not included in
worksheet (230c). The default heat gain from Table 5a is
included via worksheet (70)."
Tests: 906 pass (+1), 0 fail. Pyright net-zero (35 → 35).
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||