Khalim Conn-Kowlessar 34cbd7d66c feat(pcdb): parse Table 323 (Centralised MEV / MVHR) + Table 329 efficiency IUF
MVHR (24a) heat-recovery support, part 1: the PCDB data layer.

PCDB Table 323 (PCDF Spec Rev 6b §A.18, Format 426; pcdb10.dat carries
Format 431, header `$323,431,...`) holds the per-wet-room SFP + heat-
exchanger efficiency for centralised MEV / MVHR units. Added
`MvhrRecord` / `MvhrDataPoint`, `parse_centralised_mv_row` /
`parse_table_323`, the ETL step, the committed jsonl, and the
`mvhr_record(pcdb_id)` runtime lookup (mirrors Table 322).

SAP 10.2 §2.6.4/§2.6.6: "MVHR ... SFP is a single value depending on the
number of wet rooms" — each test group's leading field is the wet-room
count; callers select the group matching the dwelling lodgement.
Worksheet-proven on simulated case 49 (000565, 2 wet rooms, Vent Axia
Sentinel Kinetic B 500140 → flow 21.0, SFP 0.88, efficiency 91%).

Also decoded the MVHR heat-recovery efficiency in-use factor from Table
329 (Format 432): system_type 3 ducts-inside-envelope = 0.90 (case-49
(23c) = 91 × 0.90 = 81.9%), cross-checked against system_type 10 = 0.70
(= SAP 10.2 Table 4g default heat-recovery in-use factor). "Table 4h is
no longer used – data now stored in the PCDB" (SAP 10.2 p.176).

The outside-envelope efficiency columns + with-scheme SFP blocks are
preserved verbatim in `raw` (no fixture exercises them yet).

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 19:29:17 +00:00
..
pcdb feat(pcdb): parse Table 323 (Centralised MEV / MVHR) + Table 329 efficiency IUF 2026-06-23 19:29:17 +00:00
__init__.py refactor: lift-and-shift packages/domain/src/domain/sap → domain/sap10_calculator 2026-05-26 12:22:37 +00:00
table_4b.py Slice S0380.147: Appendix D Eq D1 — Table 4b non-PCDB boilers (winter/summer monthly cascade) 2026-06-01 08:22:46 +00:00
table_12.py fix(fuel): map gov-API community fuels 30/31/32 (waste/biomass/biogas) to Table-12 community rows, gated on heat-network context 2026-06-08 21:55:48 +00:00
table_12a.py feat(tariff): complete §12 Unknown-meter clause — GSHP/WSHP main triggers off-peak (RdSAP 10 PDF p.62) 2026-06-23 10:09:59 +00:00
table_13.py fix(water-heating): 18-/24-hour immersion DHW bills 100% low-rate (Table 12a scope) 2026-06-10 22:01:35 +00:00
table_32.py fix(fuel): raise UnpricedFuelCode for unrecognised fuels instead of silently defaulting to mains gas 2026-06-23 08:31:04 +00:00