Khalim Conn-Kowlessar 546bca3277 Slice S0380.177: oil 6 boiler interlock from room thermostat absence
oil 6 (B30K standard liquid-fuel boiler, Table 4b code 126 winter 80 /
summer 68) lodges Main Heating Controls Sap code 2101 ("No time or
thermostatic control of room temperature") WITH a cylinder thermostat.
The cascade's `no_interlock` gate only checked the cylinder thermostat,
so oil 6 kept raw efficiency despite the P960 worksheet header lodging
"Boiler Interlock: No".

Per RdSAP 10 §3 (PDF p.57): boiler interlock is "assumed present if
there is a room thermostat and (for stored hot water systems heated by
the boiler) a cylinder thermostat. Otherwise not interlocked." Control
code 2101 (and 2102 "Programmer, no room thermostat") provides no room
thermostat — the two Table 4e Group 1 rows carrying the "+0.6 °C /
Table 4c(2)" annotation — so the boiler is NOT interlocked regardless
of the cylinderstat. SAP 10.2 Table 4c(2) (PDF p.169) "No thermostatic
control of room temperature – regular boiler" then deducts 5pp from
BOTH the Space and DHW seasonal efficiency.

Three changes in cert_to_inputs.py:
- new `_BOILER_NO_ROOM_THERMOSTAT_CONTROL_CODES = {2101, 2102}`;
- `no_interlock` now ORs room-thermostat absence with the existing
  stored-HW cylinderstat-absence test (the RdSAP §3 conjunction);
- the Space -5pp leg fires for Table 4b non-PCDB boilers (code
  101-141), not only PCDB-record boilers; the DHW leg is gated on a
  cylinder being present (Table 4c(2) combi DHW = 0).

Result for oil 6: space fuel (211) = 13446.3457 EXACT, HW fuel (219) =
4099.5872 EXACT. ΔSAP +3.0518 → +0.0782, Δcost -£69.79 → -£1.68,
ΔCO2 -240.66 → -1.71, ΔPE -1112.66 → -18.61.

The spec-correct fix exposes a single residual cause (per
[[feedback-software-no-special-handling]]): the central heating pump
(230c) — cascade reads pump_age=2 → Table 4f 41 kWh but ws (230c) =
53.3 kWh. The 12.3 kWh gap fully accounts for the residual across all
three metrics; pinned as the S0380.178 forcing function.

All other 40 corpus variants + 858 section pins + 6 U985 fixtures
unchanged (2101/2102 boiler codes appear only on oil 6). Pyright
net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-04 15:40:26 +00:00
..
fixtures Slice S0380.52: cert 000565 Elmhurst-only mapper-driven cascade pin + glazing-label coverage 2026-05-28 22:03:52 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
test_elmhurst_extractor.py extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_heating_systems_corpus.py Slice S0380.177: oil 6 boiler interlock from room thermostat absence 2026-06-04 15:40:26 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_summary_pdf_mapper_chain.py Slice S0380.143: RdSAP 10 §10.11 Table 29 — derive cylinder insulation defaults from construction age band when §15.1 lodges "No Access" 2026-05-31 21:03:10 +00:00