Captures the session's window/RR/dual-main work (S0380.196–200) and the
open priority: a spec-accurate per-system boiler-interlock −5pp (Table
4c(2)) adjustment. Root cause for case 6's remaining deltas (sys-1 eff 79
not 84 + HW 4824 vs 4902) is the "room thermostat present but no cylinder
thermostat → no interlock" path that the current {2101,2102} no-interlock
rule misses. 0240 shares the controls + cylinder_thermostat=N so it will
re-pin (apply spec uniformly). Secondary: dual-system Table 4f pumps.