Model/tests
Khalim Conn-Kowlessar 5d556faf86 fix(roof): bill at-rafters insulation on RdSAP 10 Table 16/18 column (2)
`u_roof` only implemented the joist column, so roofs lodged insulated at
rafters (`roof_insulation_location == 1`) were mis-billed at the joist U
on both the API and Summary paths — under-stating loss, over-rating SAP.

RdSAP 10 §5.11.2 Table 16 (spec p.42-43) gives a distinct "insulation at
rafters" column (2): the rafter cavity is shallower than a loft void, so
the same depth yields a higher U (200 mm: rafters 0.29 vs joists 0.21).
§5.11 Table 18 (p.45) likewise carries a rafters column (2) for unknown /
as-built thickness (footnote (1): "The value from the table applies for
unknown and as built") — band A-D = 2.30, E = 1.50, F = 0.68, diverging
from the joist column's 100 mm-equivalent 0.40 default (footnote (4)).

- add `_ROOF_RAFTERS_BY_THICKNESS` (Table 16 col 2) + `_ROOF_RAFTERS_BY_AGE`
  (Table 18 col 2) to rdsap_uvalues; `u_roof` selects them via a new
  `insulation_at_rafters` flag (ignored for flat / sloping-ceiling roofs).
- `heat_transmission` derives the flag PER BUILDING PART from
  `roof_insulation_location` (gov-API int 1 / Summary "R Rafters"), which
  also fixes the multi-part dedup-roof-join problem: each part's own
  location now drives its U, replacing the unattributable joined
  `epc.roofs[]` description.

Worksheet-validated to 1e-4: simulated case 41 (4-bp — Ext1 rafters 200mm
→ 0.29, Ext3 rafters As-Built band F → 0.68; roof total 24.8350) and case
42 (6 variants — rafters 50mm → 0.88, rafters unknown band C → 2.30,
joists/none unchanged). Case 40 stays exact (roof 35.340, total 441.1606);
worksheet harness 47/47.

Corpus within-0.5 66.9% → 66.5% (gates 0.65/1.08 hold) — a spec-correct
shift, NOT a regression: all 15 corpus rafter certs carry redacted (None)
thickness yet lodge roof EER 2-4 (insulated), so the open API blanked a
specified thickness and the spec's unknown-rafter 2.30 default correctly
over-states them. Recovery needs a roof-EER→thickness inference on the
API path (follow-up), not a change to the U-table.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 04:42:44 +00:00
..
applications put db engine construction inside handler to avoid import errors in test 2026-06-09 15:18:42 +00:00
datatypes fix(mapper): map Elmhurst "Value known" cylinder to measured volume (code 6) 2026-06-15 23:57:25 +00:00
domain fix(roof): bill at-rafters insulation on RdSAP 10 Table 16/18 column (2) 2026-06-16 04:42:44 +00:00
harness test(harness): re-pin golden-cert plans to the gain-maximising packages 2026-06-15 13:57:27 +00:00
infrastructure fix(roof): bill at-rafters insulation on RdSAP 10 Table 16/18 column (2) 2026-06-16 04:42:44 +00:00
magic_plan Migrate all MagicPlan tests to single new-format fixture 🟪 2026-06-05 12:59:56 +00:00
orchestration Merge pull request #1217 from Hestia-Homes/feature/per-cert-mapper-validation 2026-06-15 15:03:05 +01:00
repositories Merge branch 'main' of https://github.com/Hestia-Homes/Model into feature/junte+khalim 2026-06-12 13:45:30 +00:00
scripts fix terraform error and pass handler bool for dry runs 2026-06-15 14:06:54 +00:00
utilities added floats helper 2026-06-12 14:28:41 +00:00
__init__.py added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
conftest.py Audit generator populates XLSX, uploads to S3, and records UploadedFile row 🟪 2026-06-09 12:05:55 +00:00
test_lambda_packaging.py more tests to ensure we don't deploy something that is brokern 2026-06-02 15:03:20 +00:00