mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
Wires PCDB main heating index + secondary heating type into the three open fixtures. All three certs lodge: - Vaillant ecoTEC PCDB index (000480=16839 pro 28, 000487=18119 sustain 28, 000516=18118 sustain 24) at main_heating_data_source=1. - Electricity Electric Panel/convector secondary (SAP code 691) at Table 11 fraction 0.10 (gas main + any secondary, page 188). - number_baths (000480=0, 000487=1, 000516=1). Confirmed against SAP 10.2 (14-03-2025) Table 11 page 188: "All gas, liquid and solid fuel systems" main + "all secondary systems" → fraction 0.10. PDF arithmetic on each fixture matches: 000480: 12398.58 × 0.10 = 1239.86 kWh secondary ✓ 000487: 10834.78 × 0.10 = 1083.48 kWh secondary ✓ 000516: 12410.32 × 0.10 = 1241.03 kWh secondary ✓ Impact on continuous SAP delta (target <0.01): fixture | pre S18a | post S18a | status --------|----------|-----------|--------- 000480 | +7.0885 | +0.0012 | ✓ within 0.01 000487 | +5.5285 | -1.9586 | over-corrected 000516 | +6.8375 | +0.0349 | nearly closed (0.04) 000480 hits the 0.01 continuous gate — first time outside 000490. 000516 is within 0.04 (was +6.84). 000487 swung from +5.5 to -2.0, suggesting the PCDB 18119 efficiency cascade diverges from what the PDF assumes for that specific boiler — separate slice. The previous fixture-lodgement gap was the dominant cost residual: (242) secondary cost was £0 and (240) main heating was over-counting because no PCDB efficiency was applied. Both close in this slice. The remaining (251) standing charges (£120) gap is a calculator-side issue addressed in the next slice (Table 12a page 191). Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com> |
||
|---|---|---|
| .. | ||
| src/domain | ||
| pyproject.toml | ||
| README.md | ||
domna-domain
Shared domain types — Property, Properties, BaselinePerformance, Plan, PlanPhase, Scenario, ScenarioPhase, ScenarioSnapshot, Recommendation, OptimisedPackage, EpcPropertyData, etc.
Boundary: types only. No persistence, no IO, no business logic. Other packages and services depend on domna-domain; this package depends on nothing internal.
Domain definitions live in ../../CONTEXT.md. New types added here must match the glossary terms.
Layout
src/domain/
├── __init__.py
├── property.py # Property, Properties, PropertyIdentity
├── site_notes.py
├── landlord_overrides.py
├── baseline_performance.py # lodged + effective pair (ADR-0004)
├── plan.py # Plan, PlanPhase, OptimisedPackage
├── scenario.py # Scenario, ScenarioPhase, ScenarioSnapshot (ADR-0005)
├── recommendation.py
├── geospatial.py
├── solar.py
├── anomaly_flags.py
└── ml/
├── __init__.py
├── transform.py # EpcMlTransform (versioned per §8.3)
└── schema.py
When datatypes/epc/domain/ folds in, the EPC schema types move under src/domain/epc/.