Khalim Conn-Kowlessar 5e7ef5c7ff fix(control): no boiler interlock for TRVs+bypass controls 2107/2111 (SAP §9.4.11)
`_BOILER_NO_ROOM_THERMOSTAT_CONTROL_CODES` held only {2101, 2102} — it was
keyed off the Table 4e "+0.6 °C" annotation rather than the actual interlock
criterion. SAP 10.2 §9.4.11 (PDF p.66): "A boiler system with no room
thermostat (or a device equivalent in this context, such as a flow switch or
boiler energy manager) ... must be considered as having no interlock", and
"TRVs alone ... do not perform the boiler interlock function". A fixed bypass
likewise provides no interlock (it keeps water circulating when TRVs close).

So control 2107 ("Programmer, TRVs and bypass") and 2111 ("TRVs and bypass")
lack interlock and must take the Table 4c(2) −5pp Space+DHW seasonal-efficiency
adjustment and the Table 4f footnote a) ×1.3 circulation-pump uplift — both of
which they previously missed. (2108 flow switch / 2109 boiler energy manager
carry interlock-equivalent devices → excluded; 2103-2106/2113 have a room
thermostat.) All affected certs are cat-2 gas boilers, where §9.4.11 applies.

Eval: 909 computed, 45.3% → 46.9% within 0.5 (+14 certs: 412 → 426), mean|err|
1.659 → 1.633. Bucket means corrected: control 2107 +1.50 → +0.32 (n=38),
2111 +1.48 → +0.16 (n=4). 32 improved / 10 regressed (all small; the six that
crossed out of ±0.5 were coincidentally-accurate offsetting-error certs).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 13:17:15 +00:00
..
addresses standardist Address 2026-05-22 10:13:32 +00:00
data_transformation moved classifier data transformation to an easy one 2026-06-01 14:53:34 +00:00
epc Remove EPC and asset_list changes unrelated to SAL handler 2026-06-01 16:39:09 +00:00
fuel_rates feat(fuel-rates): FuelRates snapshot + repository foundation (ADR-0014) 2026-06-02 09:29:07 +00:00
geospatial feat(geospatial): GeospatialRepo — OS Open-UPRN coordinate lookup (#1131) 2026-06-01 16:28:48 +00:00
property feat(property): Property aggregate + PropertyRepository (#1132) 2026-06-01 16:28:48 +00:00
property_baseline feat(baseline): sap_code_to_fuel normalizes via the calculator's own helper 2026-06-05 18:59:25 +00:00
sap10_calculator fix(control): no boiler interlock for TRVs+bypass controls 2107/2111 (SAP §9.4.11) 2026-06-08 13:17:15 +00:00
sap10_ml fix(u-value): RdSAP10 ignores gov-API wall insulation conductivity → §5.8 default λ 2026-06-07 18:39:01 +00:00
tasks added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
postcode.py get rid of comments 2026-05-20 13:21:11 +00:00