`_BOILER_NO_ROOM_THERMOSTAT_CONTROL_CODES` held only {2101, 2102} — it was
keyed off the Table 4e "+0.6 °C" annotation rather than the actual interlock
criterion. SAP 10.2 §9.4.11 (PDF p.66): "A boiler system with no room
thermostat (or a device equivalent in this context, such as a flow switch or
boiler energy manager) ... must be considered as having no interlock", and
"TRVs alone ... do not perform the boiler interlock function". A fixed bypass
likewise provides no interlock (it keeps water circulating when TRVs close).
So control 2107 ("Programmer, TRVs and bypass") and 2111 ("TRVs and bypass")
lack interlock and must take the Table 4c(2) −5pp Space+DHW seasonal-efficiency
adjustment and the Table 4f footnote a) ×1.3 circulation-pump uplift — both of
which they previously missed. (2108 flow switch / 2109 boiler energy manager
carry interlock-equivalent devices → excluded; 2103-2106/2113 have a room
thermostat.) All affected certs are cat-2 gas boilers, where §9.4.11 applies.
Eval: 909 computed, 45.3% → 46.9% within 0.5 (+14 certs: 412 → 426), mean|err|
1.659 → 1.633. Bucket means corrected: control 2107 +1.50 → +0.32 (n=38),
2111 +1.48 → +0.16 (n=4). 32 improved / 10 regressed (all small; the six that
crossed out of ±0.5 were coincidentally-accurate offsetting-error certs).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
|
||
|---|---|---|
| .. | ||