SAP 10.2 §4 line 7702 (full spec PDF p.137): "Combi loss for each month
from Table 3a, 3b or 3c (enter '0' if not a combi boiler)". The cascade
in `_water_heating_worksheet_and_gains` was falling through to the
Table 3a keep-hot 600 kWh/yr default whenever no PCDB Table 105 boiler
record was found — including every heat-pump cert (Table 105 only
contains gas/oil boilers).
Open EPC API certs typically lodge `sap_main_heating_code = None`, so
the gate keys off `main_heating_category` instead: {1, 2} for the
gas/oil/solid-fuel boiler family + {3, 6} for community heat networks
(preserves the existing DLF-scaling regression test). Categories 4
(heat pump), 5 (warm air), 7 (electric storage), 10 (room heaters) and
all other non-combi mains zero (61)m per the spec parenthetical.
Cert 0380 (Mitsubishi ASHP, cat=4): HW kWh/yr drops 503.08 → 242.21,
removing the bogus 600 kWh × 0.18 £/kWh = £77/yr inflation. Closed
boiler certs (001479, 0330, 9501 — all cat=2) and heat-network cert
parity unchanged.
|
||
|---|---|---|
| .. | ||