Model/backend/documents_parser/tests/fixtures
Khalim Conn-Kowlessar 62fc27a5cc S0380.193: suspended-floor (12) sealed rule fires only on a SUPPLIED U-value
RdSAP 10 §5 (PDF p.29) "Floor infiltration (suspended timber ground
floor only)", age band A-E, splits on whether a floor U-value is
supplied:
  a) [U-value supplied] if floor U-value < 0.5 → "sealed", (12) = 0.1
  b) [no U-value supplied] retro-fitted insulation → "sealed" 0.1;
     otherwise "unsealed", (12) = 0.2

`_has_suspended_timber_floor_per_spec` fed the cascade's COMPUTED default
U into rule (a), so an as-built/uninsulated suspended-timber floor whose
default U happens to be < 0.5 was marked "sealed" (0.1) where Elmhurst
uses "unsealed" (0.2). That dropped (18) infiltration 0.85 → 0.75, (25)
effective ACH, HTC, and understated space heating ~450 kWh.

Fix: gate rule (a) on `floor_u_value_known` — a computed default U is not
a supplied value, so it falls through to (b). Verified against the
cert 001431 sim-case-2 worksheet: floor "As built", U=0.43 (matches the
worksheet's (28a) 0.4300 exactly), (12)=0.2 unsealed. Golden cert 6035
(also a suspended uninsulated floor) is unaffected — its U=0.63 ≥ 0.5
already routed to unsealed.

Promotes sim case 2 to the e2e harness as `001431_rr` (Main + Extension
+ Simplified room-in-roof — the 6035 archetype). All 11 Block-1 line
refs pin at abs=1e-4, locking BOTH this fix and S0380.192 (Simplified-RR
remaining area) end-to-end: SAP 69, cost 920.5046, CO2 4566.7090, space
15269.8593, main fuel 18178.4039. 2319 passed (+11), 0 failed; pyright
net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-03 09:16:25 +00:00
..
elmhurst_site_notes_1_text.json elmhurst site notes fixture 2026-04-24 13:09:30 +00:00
elmhurst_site_notes_2_text.json extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
ElmhurstSiteNotes.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
ElmhurstSiteNotes_2.pdf extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
pashub_site_notes_1_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_2_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_3_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_4_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_5_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_6_text.json rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
pashub_site_notes_7_text.json Extract address when Property photo element is missing from PDF 🟩 2026-04-30 16:25:41 +00:00
PasHubSiteNotes_1.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_2.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_3.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_4.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_5.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_6.pdf rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
PasHubSiteNotes_7.pdf Extract address when Property photo element is missing from PDF 🟩 2026-04-30 16:25:41 +00:00
Summary_000474.pdf Scaffold: end-to-end Summary→EpcPropertyData chain test for 000474 (xfail) 2026-05-24 17:40:06 +00:00
Summary_000477.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000480.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000487.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000490.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000516.pdf Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added 2026-05-24 19:17:59 +00:00
Summary_000565.pdf Slice S0380.52: cert 000565 Elmhurst-only mapper-driven cascade pin + glazing-label coverage 2026-05-28 22:03:52 +00:00
Summary_000784.pdf chore: stage cert 9501 fixtures (second boiler validation cert) 2026-05-26 18:53:08 +00:00
Summary_000884.pdf Slice S0380.16: add 'Normal' → cylinder_size=2 (110 L) for cohort 2 2026-05-27 22:44:02 +00:00
Summary_000888.pdf Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
Summary_000889.pdf Slice S0380.16: add 'Normal' → cylinder_size=2 (110 L) for cohort 2 2026-05-27 22:44:02 +00:00
Summary_000890.pdf Slice S0380.19: count Elmhurst shower outlets by type (no more hardcoded 1) 2026-05-28 07:16:32 +00:00
Summary_000897.pdf chore: stage cert 0330 fixtures (boiler pilot) 2026-05-26 17:37:14 +00:00
Summary_000898.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000899.pdf chore: stage cert 0380 fixtures (HP pilot — deferred workstream) 2026-05-26 17:37:34 +00:00
Summary_000900.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000901.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000902.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000903.pdf Slice S0380.9: multi-array PV support + close cert 0350 to ASHP spec floor 2026-05-27 20:44:13 +00:00
Summary_000904.pdf Slice S0380.10: pin certs 3800 + 9285 Summary chain tests — first-try closure 2026-05-27 20:47:51 +00:00
Summary_000910.pdf Slice S0380.18: u_party_wall flat default per RdSAP10 Table 15 footnote* 2026-05-27 23:24:58 +00:00
Summary_001431_gas_combi.pdf S0380.191: pin simulated 001431 gas-combi end-to-end at 1e-4 (e2e harness) 2026-06-02 22:44:32 +00:00
Summary_001431_rr_ext.pdf S0380.193: suspended-floor (12) sealed rule fires only on a SUPPLIED U-value 2026-06-03 09:16:25 +00:00
Summary_001479.pdf Slice 54: Elmhurst mapper sets extensions_count from len(survey.extensions) 2026-05-24 22:15:47 +00:00