Khalim Conn-Kowlessar 6636f1c333 Slice S0380.141: §9.4.11 boiler interlock — extend −5pp adjustment to both space-heating efficiency and the PCDB Equation D1 water cascade
SAP 10.2 §9.4.11 (PDF p.30) "Boiler interlock":

  For the purposes of the SAP, an interlocked system is one in which
  both the space and stored water heating are interlocked. If either
  is not, the 5% seasonal efficiency reduction is applied to both
  space and water heating; if both are interlocked no reductions are
  made.

Table 4c (PDF p.169-170) lodges -5 for both Space and DHW columns on
the "No boiler interlock — regular boiler" row. Pre-slice the cascade
applied the -5pp adjustment ONLY to the `water_eff` scalar fallback
(`cert_to_inputs.py:4354`) and missed:

  (a) the SH efficiency path (cascade kept the raw PCDB winter eff for
      space heating);
  (b) the PCDB Equation D1 monthly cascade (Eq D1 received raw
      winter/summer values without the -5pp adjustment).

RdSAP §3 (PDF p.57) defines boiler interlock as "Assumed present if
there is a room thermostat and (for stored hot water systems heated
by the boiler) a cylinder thermostat. Otherwise not interlocked."
Cert pcdb 1 (Potterton KOA PCDB 716 + 110 L cylinder + Cylinder Stat:
No) reproduces the pattern: worksheet (210) = 60% = PCDB winter
65 - 5; worksheet (217)m monthly Eq D1 pivots on (winter 60,
summer 48) not (65, 53).

The SH path is further gated on `pcdb_main is not None` because
§9.4.11 only applies to "gas and liquid fuel boilers" — cert 000565
(ASHP Main 1) keeps its raw SH eff. The combi-fed-cylinder DHW path
(cert 000565 WHC 914 to PCDB combi Main 2) continues to receive its
existing -5pp via the `water_pcdb_main` gate (unchanged).

Corpus impact: pcdb 1 SAP residual +6.95 → +3.40; cost -£157.61 →
-£75.68; CO2 -845.81 → -397.02; PE -3135.30 → -1601.74. No other
variant has PCDB main + cylinder + no thermostat, so the other 24
corpus pins are unchanged.

Extended handover suite: 884 pass, 0 fail (was 883 + 1 new AAA test
pinning the §9.4.11 SH eff path).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-05-31 20:33:01 +00:00
..
fixtures Slice S0380.52: cert 000565 Elmhurst-only mapper-driven cascade pin + glazing-label coverage 2026-05-28 22:03:52 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
test_elmhurst_extractor.py extract window frame details from elmhurst site notes 🟥 2026-04-27 15:50:25 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_heating_systems_corpus.py Slice S0380.141: §9.4.11 boiler interlock — extend −5pp adjustment to both space-heating efficiency and the PCDB Equation D1 water cascade 2026-05-31 20:33:01 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_summary_pdf_mapper_chain.py Slice S0380.133: derive solid-fuel main fuel from §14.0 EES Code 2026-05-31 10:04:28 +00:00