Model/domain
Khalim Conn-Kowlessar 698c61950e Slice S0380.178: oil 6 circulation pump x1.3 for absent room thermostat
Closes the residual S0380.177 exposed on oil 6. The cascade's central
heating pump used the bare Table 4f age default (41 kWh for "2013 or
later") but the worksheet (230c) = 53.3 kWh.

SAP 10.2 Table 4f (PDF p.175) footnote a) on the "Circulation pump"
rows reads verbatim: "Multiply by a factor of 1.3 if room thermostat
is absent." oil 6 lodges control code 2101 ("No time or thermostatic
control of room temperature") = no room thermostat, so 41 x 1.3 = 53.3
= ws (230c) EXACTLY; pumps/fans (231) = 53.3 + 100 (liquid-fuel boiler
flue fan/pump) = 153.3 EXACT. Same root cause (absent room thermostat)
as the S0380.177 Table 4c(2) interlock fix — both keyed on the new
`_BOILER_NO_ROOM_THERMOSTAT_CONTROL_CODES = {2101, 2102}`.

`_table_4f_circulation_pump_kwh` now multiplies the resolved pump kWh
by `_TABLE_4F_NO_ROOM_THERMOSTAT_PUMP_MULTIPLIER = 1.3` when the main's
control code is in that set.

oil 6 now FULLY EXACT on all four metrics (ΔSAP/cost/CO2/PE < 1e-4).
The sibling oil 5 (same "2013 or later" pump age but control 2106 WITH
a room thermostat) keeps the bare 41 kWh and is unaffected — as do the
other 39 corpus variants (2101/2102 appear only on oil 6). 935 pass;
pyright net-zero 32 -> 32.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-04 15:40:26 +00:00
..
addresses standardist Address 2026-05-22 10:13:32 +00:00
data_transformation moved classifier data transformation to an easy one 2026-06-01 14:53:34 +00:00
epc Remove EPC and asset_list changes unrelated to SAL handler 2026-06-01 16:39:09 +00:00
geospatial feat(geospatial): GeospatialRepo — OS Open-UPRN coordinate lookup (#1131) 2026-05-30 19:55:46 +00:00
property feat(property): Property aggregate + PropertyRepository (#1132) 2026-05-30 19:39:54 +00:00
property_baseline refactor(property-baseline): rename baseline → property_baseline aggregate (PR #1139 review) 2026-06-01 14:54:59 +00:00
sap10_calculator Slice S0380.178: oil 6 circulation pump x1.3 for absent room thermostat 2026-06-04 15:40:26 +00:00
sap10_ml Slice S0380.109: Solid brick + insulation via §5.7 Table 13 + §5.8 Table 14 (RdSAP 10) 2026-05-30 18:10:33 +00:00
tasks added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
postcode.py get rid of comments 2026-05-20 13:21:11 +00:00