Model/harness/sample_catalogue.json
Khalim Conn-Kowlessar 07f534ee11 feat(modelling): system tune-up options (standard + zone controls)
Add the system tune-up to the heating Recommendation: keep the existing wet
boiler but install better heating controls and fix the cylinder. Two competing
Options (the Optimiser picks <=1 across the whole heating rec) per the user's
two best control end-states:

- system_tune_up        — standard controls (programmer + room thermostat +
  TRVs, SAP 10.2 Table 4e code 2106)
- system_tune_up_zoned  — time-and-temperature zone control (code 2110, type 3):
  more SAP uplift for more cost

Both keep the boiler (no fuel / SAP code / flue change), set the control
ABSOLUTELY to their end-state, and apply the conditional cylinder fixes (an
80 mm jacket when under-insulated, a thermostat when absent — only when a
cylinder exists). Each control option is offered only when it genuinely improves
the existing control — standard is skipped when the control is already 2106 /
2110 / 2112, zone when already 2110 / 2112 — so neither is ever a downgrade or a
no-op.

Validated against the Elmhurst "system tune up" re-lodgements (cert 001431):
nine befores spanning controls 2101-2113 all converge to the two common afters,
proving the control overlay is absolute. The cascade pin is parametrised over
two starting controls (2101 "no control" + 2113 "room thermostat and TRVs") x
both afters, delta 0 (SAP/CO2/PE).

Wires the two MeasureTypes through contingencies (0.15), the offline catalogue
(500 / 900), the catalogue-coverage list, the report triggers, and the ARA
first-run seed.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 10:20:46 +00:00

20 lines
1 KiB
JSON

{
"cavity_wall_insulation": { "unit_cost_per_m2": 18.5 },
"loft_insulation": { "unit_cost_per_m2": 12.0 },
"sloping_ceiling_insulation": { "unit_cost_per_m2": 40.0 },
"flat_roof_insulation": { "unit_cost_per_m2": 60.0 },
"suspended_floor_insulation": { "unit_cost_per_m2": 25.0 },
"solid_floor_insulation": { "unit_cost_per_m2": 45.0 },
"mechanical_ventilation": { "unit_cost_per_m2": 450.0 },
"external_wall_insulation": { "unit_cost_per_m2": 100.0 },
"internal_wall_insulation": { "unit_cost_per_m2": 90.0 },
"double_glazing": { "unit_cost_per_m2": 600.0 },
"secondary_glazing": { "unit_cost_per_m2": 510.0 },
"low_energy_lighting": { "unit_cost_per_m2": 8.0 },
"high_heat_retention_storage_heaters": { "unit_cost_per_m2": 3500.0 },
"air_source_heat_pump": { "unit_cost_per_m2": 12000.0 },
"gas_boiler_upgrade": { "unit_cost_per_m2": 3000.0 },
"system_tune_up": { "unit_cost_per_m2": 500.0 },
"system_tune_up_zoned": { "unit_cost_per_m2": 900.0 },
"solar_pv": { "unit_cost_per_m2": 0.0 }
}