mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
44 lines
2.7 KiB
Python
44 lines
2.7 KiB
Python
# Assumes that the average efficiency of an air source heat pump is 250%, taking the median of the 200-400% range,
|
|
# which is often quoted as a sensible efficiency range for air source heat pumps.
|
|
PESSIMISTIC_ASHP_EFFICIENCY = 200
|
|
AVERAGE_ASHP_EFFICIENCY = 300
|
|
|
|
# Conservative estimate of the proportion of electricity that will be consumed, whereas the rest will
|
|
# be exported
|
|
SOLAR_CONSUMPTION_PROPORTION = 0.5
|
|
|
|
DESCRIPTIONS_TO_FUEL_TYPES = {
|
|
"Air source heat pump, radiators, electric": {
|
|
"fuel": "Electricity", "cop": AVERAGE_ASHP_EFFICIENCY / 100
|
|
},
|
|
"Boiler and radiators, mains gas": {"fuel": 'Natural Gas', "cop": 0.9},
|
|
'Electric storage heaters': {"fuel": 'Electricity', "cop": 1},
|
|
"Electric immersion, off-peak": {"fuel": 'Electricity', "cop": 1},
|
|
"Electric storage heaters, radiators": {"fuel": 'Electricity', "cop": 1},
|
|
"Room heaters, electric": {"fuel": 'Electricity', "cop": 1},
|
|
"Electric immersion, standard tariff": {"fuel": 'Electricity', "cop": 1},
|
|
"Portable electric heaters assumed for most rooms": {"fuel": 'Electricity', "cop": 1},
|
|
"Boiler and radiators, LPG": {"fuel": 'LPG', "cop": 0.9},
|
|
"Room heaters, dual fuel (mineral and wood)": {"fuel": 'Wood Logs', "cop": 1},
|
|
"Room heaters, mains gas": {"fuel": 'Natural Gas', "cop": 0.9},
|
|
"Warm air, mains gas": {"fuel": 'Natural Gas', "cop": 0.9},
|
|
"Boiler, mains gas": {"fuel": 'Natural Gas', "cop": 0.9},
|
|
"Gas multipoint": {"fuel": "Natural Gas", "cop": 0.9},
|
|
"Warm air, Electricaire": {"fuel": "Electricity", "cop": 1},
|
|
"Gas boiler/circulator": {"fuel": "Natural Gas", "cop": 0.9},
|
|
"Boiler and underfloor heating, mains gas": {"fuel": "Natural Gas", "cop": 0.9},
|
|
"No system present: electric heaters assumed": {"fuel": "Electricity", "cop": 1},
|
|
"Electric instantaneous at point of use": {"fuel": "Electricity", "cop": 1},
|
|
"Boiler and radiators, oil": {"fuel": "Oil", "cop": 0.9},
|
|
"Electric storage heaters, Electric storage heaters": {"fuel": "Electricity", "cop": 1},
|
|
"Boiler and radiators, electric": {"fuel": "Electricity", "cop": 0.9},
|
|
"Gas boiler/circulator, no cylinder thermostat": {"fuel": "Natural Gas", "cop": 0.9},
|
|
"Boiler and radiators, dual fuel (mineral and wood)": {"fuel": "Wood Logs", "cop": 0.9},
|
|
"Electric immersion, standard tariff, plus solar": {"fuel": "Electricity + Solar Thermal", "cop": 1},
|
|
"From main system, flue gas heat recovery": {"fuel": "Natural Gas", "cop": 0.9},
|
|
"Electric underfloor heating": {"fuel": "Electricity", "cop": 1},
|
|
"No system present: electric immersion assumed": {"fuel": "Electricity", "cop": 1},
|
|
"Air source heat pump, underfloor, electric": {
|
|
"fuel": "Electricity", "cop": AVERAGE_ASHP_EFFICIENCY / 100
|
|
},
|
|
}
|