Model/tests/domain/sap10_calculator
Jun-te Kim 6f2b73e613 chore(hyde): fix window-grid automation (keep good row, delete stale below) + pin 100050881708
SOLVED the window-grid blocker (per Junte's "keep one and edit, don't
delete all"): set_single_window now ADDS the fresh window (it inserts at
DOM index 0), then deletes the STALE rows BELOW it by index (high->low,
never index 0) via the per-row Delete image button + JS-clicked Yes modal.
The freshly-added row survives as the single window; no 0.00 junk strands
to block the Recommendations gate. Verified end-to-end: cert 100050881708
built, worksheet downloaded, walls (0.70) + roof (0.19) match the engine
EXACTLY. Combined with the earlier fill+Tab (area postback) + frame/gap
(validation) fixes, the per-cert loop now runs autonomously on clean
single-main certs.

Pin: 100050881708 (semi, cavity filled, pitched 225mm, suspended ground
floor, combi) engine 72 = lodged 70 +2; walls/roof accredited-Elmhurst-
matched. NB the build entered the suspended ground floor as an upper
"above unheated space" floor, so Elmhurst's worksheet SAP (61) is not a
clean comparison — the engine uses the correct §3.12 suspended-ground U
(0.74); the pin rests on the walls+roof match + lodged.

No engine change.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 03:55:48 +00:00
..
climate Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
rdsap test(accuracy): ratchet 77.0% -> 77.3% via unsized-cylinder storage-loss fix 2026-07-02 23:02:27 +00:00
validation Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
worksheet test(accuracy): ratchet 77.3% -> 77.7% via flat-roof insulation-thickness fix (Elmhurst-validated) 2026-07-02 23:27:57 +00:00
__init__.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_bre_worked_examples.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_calculator.py Thread the off-peak meter flag and high-rate fractions onto SapResult 🟩 2026-06-24 17:45:29 +00:00
test_pcdb_etl.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_322_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_323_lookup.py feat(pcdb): parse Table 323 (Centralised MEV / MVHR) + Table 329 efficiency IUF 2026-06-23 19:29:17 +00:00
test_pcdb_table_329_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_362_lookup.py test(pcdb): PSR-extension toward 100% above largest / below smallest 🟥 2026-06-29 15:08:15 +00:00
test_postcode_weather.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_real_cert_sap_accuracy.py chore(hyde): fix window-grid automation (keep good row, delete stale below) + pin 100050881708 2026-07-03 03:55:48 +00:00
test_table_12.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12a.py feat(tariff): complete §12 Unknown-meter clause — GSHP/WSHP main triggers off-peak (RdSAP 10 PDF p.62) 2026-06-23 10:09:59 +00:00
test_table_13.py fix(water-heating): 18-/24-hour immersion DHW bills 100% low-rate (Table 12a scope) 2026-06-10 22:01:35 +00:00
test_table_32.py Map fuel code 39 (electricity, any tariff) to standard electricity 2026-06-24 11:20:32 +00:00